3
GB | Thermostat
The P5604 thermostat is designed for controlling heating and air-con-
ditioning systems.
Important
Before the rst use, make sure to carefully read the Operating
Manual for the thermostat, as well as the boiler or air-conditioning
equipment.
Turn o power supply before installing the thermostat!
Installation should be carried out by a qualied person!
During installation, follow applicable standards.
Technical specications:
Switched load: max. 230 V AC; 8 A for resistive load; 2 A for inductive
load
Clock accuracy: ±60 seconds/month
Temperature measurement: 0°C to 40°C with 0.1°C resolution
accuracy ±1°C at 20°C
Temperature setting: 5°C to 35°C in 0.5°C increments
Temperature dierential: 0.2°C
Operating temperature: 0°C to 40°C
Storage temperature: -20°C to 60°C
Power supply: 2× 1.5 V AAA batteries
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 30 × 120 × 75 mm; 125 g
Display Description (See Fig. 1)
1 – Operating mode
2 – Cooling mode
3 – Low battery indicator
4 – Current set temperature
5 – Room temperature
6 – Heating mode
Procedure for Removing the Front of the Thermostat (See Fig. 2)
Display Backlighting
Pressing the control wheel activates display backlighting for 10 seconds.
INSTALLATION
Warning:
Before replacing the thermostat, disconnect the heating/air-conditioning
system from the main power in your at. This will prevent potential injury
by electric current.