16
and day of the week (1 – Monday, 2 – Tuesday, 3 – Wednesday, 4 – Thursday,
5 – Friday, 6 – Saturday, 7 – Sunday). The time and day of the week is set
using the rotary wheel on the thermostatic head.
• Once you have set the time, conrm it by pressing the
button.
• The letters Ad will appear after conrming. Continue by pressing the
button.
• The thermostatic head will start calibrating in two steps (the steps are
indicated by a number on the screen).
• Once calibration is complete, the screen will show the current temperature
in the room and you can begin setting individual functions and modes on
the thermostatic head.
1. Setting Weekly Mode
a. To set up weekly mode, hold the
button for 5 seconds. This opens the
thermostatic head‘s settings.
b. Once you have completed the previous step, the icon will start
ashing. Press the
button to conrm your selection of Weekly Mode.
c. Next, use the rotary wheel to select which Weekly Schedule you want to
set (5+2, 6+1, 7).
d. After you have selected the Weekly Schedule, use the rotary wheel to
choose the time for the 1st time period of the workday and the temperature
for the period. Conrm the selected time and temperature by pressing the
button.
e. Once you have set the rst 6 time periods of the workday, the number 1 will
appear on the top of the screen to indicate that you are now setting time
periods for a weekend day. Set the time and temperature in the same manner
as you did for the workdays.
f. After you have set all time periods, you can either go back to setting the
thermostatic head using the
button or go to the main screen using the
button. If you conrm any action in the settings by pressing ,
the data is automatically saved.