Emotron AB 01-3991-11r2 Programming instructions and menu list 53
364 Preset frequency 3 00.0 to 200 Hz 10.0 *1
365 Preset frequency 4 00.0 to 200 Hz 20.0 *1
366 Preset frequency 5 00.0 to 200 Hz 30.0 *1
367 Preset frequency 6 00.0 to 200 Hz 40.0 *1
368 Preset frequency 7 00.0 to 200 Hz 50.0 *1
369 Preset frequency 8 00.0 to 200 Hz 60.0 *1
Process and application parameters, PID Process control
381 PID operation mode
000: PID Function unavailable
001: PID Control, Bias D control
002: PID Control, Feedback D control
003: PID Control, Bias D reverse charac-
teristics control.
004: PID Control, feedback D reverse
characteristics control.
000
382 PID Offset
000: Positive direction
001: Negative direction
000 *1
383 P: Proportional gain 0.00 to 10.0 01.0 *1
384 I: Integral time (s) 00.0 to 100 10.0 *1
385 D: Differential time (s) 0.00 to 10.0 0.00 *1
Load monitor
411 Alarm Select
000: Off
001: Min
002: Max
003: Min+Max
000 *1
412 Alarm Trip
000: Off
001: Min
002: Max
003: Min+Max
000 *1
413 Ramp Alarm
000: Off
001: On
000 *1
414 Alarm Start Delay 0 to 999 s 002 *1
415 Load Type
000: Basic
001: Load Curve
000 *1
416 Max Alarm Margin 0 to 400% 015 *1
417 Max Alarm Delay 0 to 90 s 01.0 *1
418 Max Pre-Alarm Margin 0 to 400% 010 *1
Ta bl e 2 3
Menu Function Description Range/ Code
Factory
Default
Remarks