    Karen TrujilloAug 16, 2025
    What to do if media is escaping from the Empire dust collector?
    • L
      Leah RuizAug 16, 2025
      To resolve media escaping from the Empire dust collector into the work area: * Replace leaking or refasten loose bags. * Adjust reclaimer air inlet settings. * Shake the dust bag or dust collector bags. * Replace filters if they are blinded. * Reverse the fan rotation. * Replace media and adjust the reclaimer tuning band if the media has a high dust content. * Remove obstructions from the recovery hose. * Clean the cabinet air inlet with an air line. * Tighten the dust collector door or replace the gasket if it leaks air. * Replace a worn nozzle with the recommended size (maximum ¼” diameter pressure, maximum 7/32” air jet for suction).
  • K
    Katherine RodgersAug 19, 2025
    How to improve the production rate of my Empire equipment?
    • T
      Tara MooreAug 19, 2025
      If you're experiencing a poor production rate with your Empire equipment, consider the following: * Increase blast air pressure within the specified range if it's too low. * Install a larger nozzle (and air jet on suction systems) if the current one is too small. * Ensure you are using the correct media. * Adjust media flow as needed. * Add media to maintain the recommended level. * Ensure parts are dry and free of oil or grease. * Replace old media with new and adjust the reclaimer tuning band if the media has a high dust content.
  • S
    Steve ReevesAug 22, 2025
    What to do if Empire has blast air flow, but intermittent or no media flow?
    • C
      carterpaigeAug 22, 2025
      If your Empire blast system has blast air flow, but intermittent or no media flow, consider these solutions: * Adjust and maintain pressure within the recommended range if the blast air pressure is too low. * Disassemble and clean the nozzle if it is clogged. * Remove damp media from the system and replace it with new, dry media. Also, check compressed air supply filters and avoid blasting wet or oily parts.
  • L
    lawrence90Aug 25, 2025
    What causes intermittent media flow in my Empire blast system?
    • S
      Steven PriceAug 26, 2025
      If your Empire system exhibits blast air flow with intermittent or no media flow (continued), check these points: * For suction systems, ensure the nozzle orifice size is twice the air jet orifice size (e.g., 1/8” diameter air jet requires minimum ¼” diameter nozzle). * For suction systems, adjust the media hose in the media regulator and ensure an airtight seal at the suction gun body. * For suction systems, clear a clogged media hose by blowing air through it. * For pressure systems, adjust the media regulator if it's closed. * For pressure systems, check for and repair compressed air leaks in the sealing plunger or exhaust valve. * For pressure systems, clear any obstruction in the Sure-Flo media regulator.
  • D
    Diane HullAug 28, 2025
    How to stop static charge build-up in Empire equipment?
    • S
      Sarah DominguezAug 28, 2025
      If you're experiencing static charge build-up and discharge from your Empire equipment, consider the following: * Replace the blast hose with one of high quality if the current one is a poor conductor. * Earth ground the system properly. * Place the part on a metal surface if it's insulated or resting on a rubber mat. * Install an Empire Anti Static Strap, part 510411, if there is low compressed air and ambient humidity.
  • M
    Michele DiazAug 31, 2025
    What to do if there is no air or media flow from the Empire nozzle?
    • J
      Jody RoweAug 31, 2025
      If there is no air or media flow from the Empire nozzle, make sure that: * All air valves from the compressor are open. * The cabinet doors are tightly closed, sealing the door interlock. * The regulator is adjusted. * The nozzle is disassembled and cleaned. * The door interlock air hose is replaced. If the problem continues, further pneumatic control circuit troubleshooting may be required.
  • M
    Mark GallagherSep 3, 2025
    Why won't the blast activate on my Empire system?
    • T
      Trevor WilkinsSep 3, 2025
      If the lights and blower are working but the blast will not activate on your Empire system, try the following: * Repair any air leaks. * Verify the main air supply is on and the cabinet is receiving air, and the regulator is set properly. * Check for obvious control air leaks. * Listen for air leaks with the main switch ON and foot treadle pressed. * Check for air leaks between points B and C. * If no air escapes when the foot treadle valve is manually pressed, replace the valve.
  • C
    Christopher HernandezSep 6, 2025
    Why is good media being carried to the Empire dust collector?
    • D
      Derek DownsSep 6, 2025
      To address good media being carried to the Empire dust collector: * Continue use until a bag “cake” forms (approximately eight hours of operation). * Adjust the tuning band. * Add media to the recommended level if there is insufficient media in the suction hopper. * Adjust the slide gate. * Use more coarse media. * Replace the plunger and/or sealing ring if a worn plunger or sealing ring is leaking air into the reclaimer in pressure systems.
  • M
    Michelle GibsonSep 9, 2025
    Why is there a delay in blast activation with my Empire foot treadle?
    • A
      Andrew ZimmermanSep 9, 2025
      To address excessive delay between stepping on the foot treadle and blast activation in your Empire system: * Adjust the foot treadle tab if it does not fully press the foot treadle valve plunger. * Check the condition of the control air lines if they are kinked or crimped.
  • A
    Arthur BradySep 12, 2025
    How to improve visibility during blasting with Empire equipment?
    • S
      sherri53Sep 12, 2025
      To improve visibility during blasting with your Empire equipment, decrease the operating air pressure to within the recommended range if it is too high.

Summary

Preparing for Installation

Installation

Installing the System

Electrical Connections

Installing the Compressed Air Supply

General Equipment Operation

Media Selection and Use

Discusses the importance of choosing the correct media type and size for effective blasting operations.

Pneumatic Controls

Equipment Start-up

Equipment Adjustments

Helpful Hints for More Efficient Blasting

Maintenance

Troubleshooting

Troubleshooting Chart

A comprehensive chart listing common problems, their probable causes, and recommended remedies for the system.

Troubleshooting the Pneumatic Control Circuit

Warranty

Empire Pro-Finish 6060 Specifications

General IconGeneral
BrandEmpire
ModelPro-Finish 6060
CategoryOther
LanguageEnglish

Related product manuals