ENCO Control
Technical description
Kulautuvos g. 45a , LT-47190 Kaunas Tel. (+370 37) 360234 Faks. (+370 37) 360358 info@axis.lt www.axis.lt
6
Number of optically isolated discrete inputs
4
Number of optically isolated power outputs
(NO semiconductor relays) AC 110-230V, <1.2 A
for each, total load (current) cannot exceed 4 A.
9
Number of optically isolated current outputs
2 (may be installed under a separate
order in place of optically isolated
discrete inputs)
Inputs / outputs for connecting local devices
Number of discrete inputs
3
Number of analog inputs
1
Number of pressure measuring inputs (4-20 mA
measurement channels)
4
Number of temperature sensors
16
Communication modules and interfaces
GPRS 900/1800 MHz
1
Ethernet
1
RS232
2
3.3V
1
RS485
1
Mbus/CL
1
Card reader RFID
1
Screens displayed on LCD during operation are linked together and form well organized menu
structure. For convenience, the screens are grouped into levels. Review of menu items is
performed using five control buttons on the front panel of device or remote control buttons
(up, down, left, right, and confirm "OK"). By pressing button
next menu level, by pressing button back toward the root
of the main menu). By pressing buttons "Up" and "Down" you can select the appropriate
menu item.
It is possible to view and set up all the main settings of device: