EasyManua.ls Logo

Endless Summer 153100 - User Manual

Endless Summer 153100
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Owners Manual
Manueal d’Utilisation
Model No.
153100
AVERTISSEMENT
POUR VOTRE SECURITE:
A Utiliser Uniquement a
l’Exterieur
(hors de tout abri clos)
AVERTISSEMENT
POUR VOTRE SECURITE:
Tout mauvais reglage ainsi que
toute installation, modication,
ou maintenance incorrecte
risque de provoquer des
blessures ou des degats
materiels. Lir completement
les instructions concernant
l’installation, le fonctionnement
et l’entretien avant d’installer ou
de proceder a la maintenance de
cet appareil.
U.S. Patent Number: 6,470,877
Les ETATS-UNIS font breveter
le nombre : 6,470,877
WARNING
FOR YOUR SAFETY
For Outdoor Use Only
(Outside any enclosure)
WARNING
FOR YOUR SAFETY
Improper installation,
adjustment, alteration,
service or maintenance
can cause injury or property
damage. Read the installation,
operation and maintenance
instructions thoroughly before
installing or servicing this
equipment.

Questions and Answers

  • J
    Jeremy JacobsonAug 17, 2025
    Why won't the pilot light on my Endless Summer Patio Heater?
    • C
      Chelsea JamesAug 17, 2025
      Several factors can prevent the pilot light from igniting on your Endless Summer Patio Heater. It could be due to a closed tank valve (open the valve to resolve this), a blockage in the orifice or pilot tube (clean or replace these parts), air in the gas line (bleed the gas line by pressing the control knob for 1-2 minutes until you smell gas), low gas pressure (replace the tank), or a faulty igniter (use a match to light the pilot and replace the igniter).
  • J
    James McgeeAug 20, 2025
    What to do if my Endless Summer 153100 burner won’t light?
    • M
      Mark HaynesAug 20, 2025
      If the burner on your Endless Summer Patio Heater fails to light, the issue might stem from low gas pressure (turn the tank valve OFF and replace the tank). Alternatively, there could be a blockage in the orifice (clear the blockage), or the control knob might not be in the ON position (turn the control knob to ON).
  • Q
    qcantuAug 22, 2025
    What to do if pilot won’t stay lit on Endless Summer 153100?
    • L
      logan66Aug 22, 2025
      If the pilot light on your Endless Summer Patio Heater won't stay lit, it could be due to dirt buildup around the pilot (clean the dirt). Another cause might be a loose connection between the gas valve and pilot assembly (tighten the connection and perform a leak check). Lastly, the thermocouple might not be operating correctly (replace the thermocouple).
  • D
    David PetersAug 26, 2025
    How to fix Endless Summer 153100 Patio Heater pilot that won’t light?
    • A
      ashleyandrewAug 26, 2025
      If the pilot light on your Endless Summer Patio Heater won't light, several factors could be at play. First, ensure that the cylinder valve is open. If it is, there might be a blockage in the orifice or pilot tube, requiring cleaning or replacement. Another possibility is air in the gas line; in this case, open the gas line and bleed it by pressing the control knob for up to two minutes, or until you smell gas. Low gas pressure can also be the culprit, so turn the cylinder valve off and replace the cylinder. Lastly, if the igniter is faulty, try lighting the pilot with a match and replace the igniter.
  • J
    johngardnerAug 28, 2025
    What to do if the pilot won’t stay lit on Endless Summer 153100?
    • K
      Kaitlin DominguezAug 28, 2025
      If the pilot light on your Endless Summer Patio Heater won't stay lit, it might be due to dirt accumulation around the pilot; clean the area around the pilot. Check the connection between the gas valve and pilot assembly; if it's loose, tighten it and perform a leak check. A faulty thermocouple can also cause this issue, so consider replacing it.
  • D
    Dean AtkinsonAug 31, 2025
    Why won't the burner light on my Endless Summer 153100 Patio Heater?
    • M
      Mallory FrenchAug 31, 2025
      If the burner on your Endless Summer Patio Heater won't light, check if the gas pressure is low. If so, turn the cylinder valve off and replace the cylinder. Also, inspect the orifice for any blockages and clear them. Finally, ensure that the control knob is in the ON position.
  • D
    David WoodsSep 2, 2025
    Why is the burner flame low on my Endless Summer 153100?
    • E
      Eddie GarrettSep 3, 2025
      A low burner flame on your Endless Summer Patio Heater can be attributed to several reasons: low gas pressure (turn the tank valve OFF and replace the tank), outdoor temperature being below 40ºF with a tank less than 1/4 full (use a full tank), a bent or kinked supply hose (straighten the hose), or a blockage in the burner and orifices (check for and clear any blockages).
  • M
    Michael MartinezSep 5, 2025
    Why does my Endless Summer Patio Heater emitter glow unevenly?
    • V
      Vincent WarrenSep 5, 2025
      Uneven glowing of the emitter on your Endless Summer Patio Heater can occur due to low gas pressure (turn the tank valve OFF and replace the tank). It may also happen if the base is not on a level surface (place the heater on a level surface), or the burner needs cleaning (clean the burner).
  • M
    Mrs. Nicole GonzalezSep 8, 2025
    What to do if Endless Summer 153100 produces thick black smoke?
    • T
      Tammy MillerSep 8, 2025
      If your Endless Summer Patio Heater is emitting thick black smoke, there is likely a blockage in the burner. Remove the blockage and clean the burner inside and outside.
  • K
    Kelly LambertSep 12, 2025
    How to fix uneven glowing emitter on Endless Summer 153100?
    • S
      Scott TerrySep 12, 2025
      If the emitter on your Endless Summer Patio Heater glows unevenly, it could be due to low gas pressure; turn the cylinder valve off and replace the cylinder. Ensure the base is on a level surface. If the heater is level, the burner may need cleaning.

Summary

Assembly Instructions

General Components & Features

Familiarize yourself with all components before proceeding. Refer to page 5 for hardware and components, and page 20 for specifications.

Additional Requirements

The following items are not included, but are necessary for the proper assembly of your heater.

Operation

Before Turning Gas Supply ON

Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a building, garage, or any other enclosed area.

Before Lighting

Heater should be thoroughly inspected before each use, and by a qualified service person at least annually.

Lighting

This heater is equipped with a Pilot Light that allows for safer startups and shutdowns. Pilot must be lit before Main Burner can be started.

Re-lighting

For your safety, Control Knob cannot be turned OFF without first depressing Control Knob in PILOT position and then rotating it to OFF.

Shut Down

Turn Control Knob clockwise to Pilot. (Normally, burner will make a slight popping sound when extinguished.)

Operation Checklist

For a safe and pleasurable heating experience, perform this check before each use.

Troubleshooting

Maintenance

Storage

Service

Limited Warranty

Specifications

Endless Summer 153100 Specifications

Rating and Heat Range IconRating and Heat Range
maximum BTU input40, 000 BTU/hr
heat range diameter20 foot
Fuel and Pressure IconFuel and Pressure
fuel typeLiquid Propane Gas (LP)
cylinder size20 lb / 5 Gallon
maximum inlet gas supply pressure150 PSI
minimum inlet gas supply pressure5 PSI
manifold pressure11.00 in. W.C.