EasyManua.ls Logo

Endress+Hauser ISEmax compressed air cleaning unit - Repairs

Endress+Hauser ISEmax compressed air
cleaning unit
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISEmax compressed air cleaning unit (230 V AC) Repairs
Endress+Hauser 17
Assembly
1. Place the thrust washer back on the connecting rod disk and seal lip.
2. Screw on the fillister-head screw securely.
The seal lip should not become warped and the pretension should cause it to fit
properly in the cylinder.
3. Place the spacer on the connecting rod disk.
Make sure it is positioned correctly in the corresponding recesses.
4. Check the seal (item 2) of the ribbed cover.
and replace if necessary.
5. Insert the intermediate plate into the ribbed cover.
Make sure it is seated correctly (outline of thrust ring and outline of ribbed cover
for bottom and top position respectively; position in the ribbed cover is clear).
6. Place the ribbed cover together with the intermediate plate and seal on the pump head
so that the logo on the ribbed cover is over the fan grill.
7. Screw the 4 Allen screws tight.
The spare parts kit also contains 2 additional valve springs (item 4), including the
associated screws and a valve guard (item 3). Replace these parts only if necessary.
9 Repairs
9.1 Spare parts
Compressor spare parts kit:
1 seal lip
1 seal for ribbed cover
1 O-ring Ø 70 x 2.0
1 valve guard
2 valve springs
2 fillister-head screws DIN84, M3x4
Order No. 71092783
9.2 Return
The product must be returned if repairs or a factory calibration are required, or if the wrong
product was ordered or delivered. As an ISO-certified company and also due to legal
regulations, Endress+Hauser is obliged to follow certain procedures when handling any
returned products that have been in contact with medium.
To ensure the swift, safe and professional return of the device:
Refer to the website www.endress.com/support/return-material for information on the
procedure and conditions for returning devices.