EasyManua.ls Logo

Endress+Hauser Micropilot FMR52 - Post-connection Check

Endress+Hauser Micropilot FMR52
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus The "Expert" menu
Endress+Hauser 41
Write access Maintenance
Prerequisite Medium type = Solid
Description Select maximum expected filling speed.
Options Very slow < 0.5m (1.6ft) /h
Slow < 1 m (3.3ft) /h
Standard < 2m (6,5ft) /h
Medium < 4m (13ft) /h
Fast < 8m (26ft) /h
Very fast > 8m (26ft) /h
No filter / test
Factory setting Standard < 2m (6,5ft) /h
Additional information The Max. filling speed solid parameter must be set according to the actual process
velocity.
Max. draining speed solid (1213)
Navigation Expert → Sensor → Max. draining speed solid
Write access Maintenance
Prerequisite Medium type = Solid
Description Select maximum expected draining speed.
Options Very slow < 0.5m (1.6ft) /h
Slow < 1 m (3.3ft) /h
Standard < 2m (6,5ft) /h
Medium < 4m (13ft) /h
Fast < 8m (26ft) /h
Very fast > 8m (26ft) /h
No filter / test
Factory setting Standard < 2m (6,5ft) /h
Additional information The Max. draining speed solid parameter must be set according to the actual process
velocity.
Advanced process conditions (1177)
Navigation Expert → Sensor → Advanced process conditions
Write access Maintenance
Description Defines additional process conditions (if necessary)

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR52

Related product manuals