Soliwave FQR56/FDR56
Installation
Endress+Hauser 17
A
α α
D
7 Paralleloperation
A Distancebetweenmicrowavebarriers
D Detectiondistance
α 90°
Whenusingdierentmodulationfrequenciesandoperationasshownintheexamplefor
paralleloperation,thefollowingdependencyofthedetectiondistanceD to the distance of the
individual microwave barriers A applies.
20
40
60
80
100
120
140
160
180
200
40
30
20
10
0
A
min
[cm]
D [cm]
8 Dependencyofdetectiondistancetothedistanceofthemicrowavebarriers
•Usethechannelsinsequentialorder,i.e.1,2,etc.to5,thenbackto1,etc.
• No settings are necessary on the FDR56 transceiver.
Details on the settings
→33