EasyManua.ls Logo

Endress+Hauser Cerabar S PMP71 User Manual

Endress+Hauser Cerabar S PMP71
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BA00303P/00/EN/13.11
71139808
valid from Software version:
03.00.zz
Operating Instructions – Description of Device Functions
Cerabar S PMC71, PMP71/75
Deltabar S FMD76/77/78, PMD70/75
Deltapilot S FMB70
Process pressure / Differential pressure, Flow / Hydrostatic

Table of Contents

Other manuals for Endress+Hauser Cerabar S PMP71

Questions and Answers:

Endress+Hauser Cerabar S PMP71 Specifications

General IconGeneral
Device TypePressure Transmitter
ManufacturerEndress+Hauser
ModelPMP71
Measurement PrinciplePiezoresistive
Measured variablePressure
Process PressureUp to 400 bar
Communication ProtocolHART
Diaphragm materialStainless Steel
MaterialStainless Steel
SIL suitabilitySIL 2
TypePressure transmitter
SeriesCerabar
Process Temperature-40 to 125 °C
Output Signal4 to 20 mA
Protection ClassIP66/IP67
Process connectionThread, Flange
ApprovalsATEX, IECEx

Summary

Operating Instructions – Description of Device Functions

Cerabar S PMC71, PMP71/75

Device series and models for pressure measurement.

Deltabar S FMD76/77/78, PMD70/75

Device series and models for differential pressure measurement.

Deltapilot S FMB70

Device series and models for level measurement.

Process pressure / Differential pressure, Flow / Hydrostatic

Main measurement types covered by the devices.

Notes on use

Finding parameter descriptions using ID numbers

Method to find parameter descriptions using their unique identification numbers.

Finding function groups using graphic representation

Method to find function groups using graphical representations.

Finding parameter descriptions using parameter names (index)

Method to find parameter descriptions using the index (parameter names).

Parameter description of local operation and FieldCare

Graphic representation of function groups

Representation via device display

Visual representation of function groups as displayed on the device.

Graphic representation of function groups

Representation in FieldCare

Visual representation of function groups as displayed in FieldCare software.

Pressure measurement (FF configuration program)

Level measurement (FF configuration program)

Overview of level measurement

Summary of different level measurement tasks and their configurations.

Level measurement (FF configuration program)

"Level easy pressure" level selection

Configuration for level measurement using easy pressure settings.

Level measurement (FF configuration program)

"Level easy pressure" level selection

Configuration for level measurement using easy pressure settings.

Level measurement (FF configuration program)

Calibration without reference pressure – dry calibration

Dry calibration procedure for level measurement without reference pressure.

Level measurement (FF configuration program)

"Level standard" level selection, "Linear" level mode

Standard level selection with linear mode configuration.

Flow measurement (FF configuration program)

Calibration

Calibration procedure for flow measurement.

Flow measurement (FF configuration program)

Totalizer

Configuration and operation of the totalizer function for flow measurement.

Parameter description (FF configuration program)

Cerabar S/Deltabar S/Deltapilot S block model

Overview of the device's block structure and their functions.

Parameter description (FF configuration program)

Resource Block

Detailed description of parameters within the Resource Block.

Parameter description (FF configuration program)

FOUNDATION Fieldbus Transducer Blocks standard parameters

Standard parameters applicable to all FOUNDATION Fieldbus transducer blocks.

Parameter description (FF configuration program)

Pressure Transducer Block

Description of parameters within the Pressure Transducer Block.

Parameter description (FF configuration program)

DP Flow Transducer Block (only Deltabar S)

Description of parameters specific to the DP Flow Transducer Block.

Parameter description (FF configuration program)

Analog Input Block (function block)

Description of parameters within the Analog Input Block function block.

Pressure measurement (via local operation and FieldCare)

Level measurement (via local operation and FieldCare)

Overview of level measurement

Summary of level measurement tasks, configurations, and comments.

Level measurement (via local operation and FieldCare)

"Level easy pressure" level selection

Configuration for level measurement using easy pressure settings.

Level measurement (via local operation and FieldCare)

Calibration without reference pressure – dry calibration

Dry calibration procedure for level measurement without reference pressure.

Level measurement (via local operation and FieldCare)

"Level easy height" level selection

Configuration for level measurement using easy height settings.

Level measurement (via local operation and FieldCare)

Calibration without reference pressure – dry calibration

Dry calibration procedure for level measurement without reference pressure.

Level measurement (via local operation and FieldCare)

"Level standard" level selection, "Linear" level mode

Standard level selection with linear mode configuration.

Level measurement (via local operation and FieldCare)

"Level standard" level selection, "Pressure linearized" level mode

Standard level selection with pressure linearized mode configuration.

Level measurement (via local operation and FieldCare)

Manual entry of the linearization table

Procedure for manual entry of linearization tables.

Level measurement (via local operation and FieldCare)

"Height linearized" level mode

Configuration for level measurement using height linearized mode.

Level measurement (via local operation and FieldCare)

Dry calibration and manual entry of the linearization table

Dry calibration and manual linearization table entry procedure.

Flow measurement (via local operation and FieldCare)

Calibration

Calibration procedure for flow measurement.

Flow measurement (via local operation and FieldCare)

Totalizer

Configuration and operation of the totalizer function for flow measurement.

Parameter description (Local operation and FieldCare)

Table 1: GROUP SELECTION → LANGUAGE – Local operation

Parameters for language selection in local operation.

Parameter description (Local operation and FieldCare)

Table 2: GROUP SELECTION → MEASURING MODE

Parameters for selecting the measuring mode (Pressure, Level, Flow).

Parameter description (Local operation and FieldCare)

LEVEL SELECTION (020)

Parameter for selecting the specific level mode (e.g., easy pressure, standard).

Parameter description (Local operation and FieldCare)

Table 3: QUICK SETUP "Pressure"

Quick setup parameters for pressure measurement.

Parameter description (Local operation and FieldCare)

Table 4: QUICK SETUP "Level"

Quick setup parameters for level measurement.

Parameter description (Local operation and FieldCare)

Table 5: QUICK SETUP "Flow"

Quick setup parameters for flow measurement.

Parameter description (Local operation and FieldCare)

Table 6: OPERATING MENU → SETTINGS → POSITION ADJUSTMENT

Parameters for adjusting the device's position.

Parameter description (Local operation and FieldCare)

Table 7: OPERATING MENU → SETTINGS → BASIC SETUP "Pressure"

Basic setup parameters for pressure measurement.

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Table 12: OPERATING MENU → SETTINGS → BASIC SETUP "Level", LEVEL MODE "Pressure linearized"

Basic setup for level measurement with pressure linearized mode.

Parameter description (Local operation and FieldCare)

Table 13: OPERATING MENU → SETTINGS → BASIC SETUP "Level", LEVEL MODE "Height linearized"

Basic setup for level measurement with height linearized mode.

Parameter description (Local operation and FieldCare)

Table 14: OPERATING MENU → SETTINGS → BASIC SETUP "Flow"

Basic setup parameters for flow measurement.

Parameter description (Local operation and FieldCare)

Table 15: OPERATING MENU → SETTINGS → EXTENDED SETUP "Pressure"

Extended setup parameters for pressure measurement.

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Table 20: OPERATING MENU → SETTINGS → TOTALIZER SETUP

Setup parameters for the totalizer function.

Parameter description (Local operation and FieldCare)

Table 21: OPERATING MENU → DISPLAY

Parameters related to the device display settings.

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Table 24: OPERATING MENU → TRANSMITTER INFO → PROCESS CONNECTION

Parameters for selecting and displaying the process connection type.

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Parameter description (Local operation and FieldCare)

Table 31: OPERATING MENU → PROCESSINFO → PEAK HOLD INDICATOR

Parameters related to peak hold indicators.

Parameter description (Local operation and FieldCare)

Table 32: OPERATING MENU → OPERATION

Parameters related to device operation.

Parameter description (Local operation and FieldCare)

Table 33: OPERATING MENU → DIAGNOSTICS → SIMULATION

Parameters for simulating device behavior.

Parameter description (Local operation and FieldCare)

Table 34: OPERATING MENU → DIAGNOSTICS → MESSAGES

Information about device messages and alarms.

Parameter description (Local operation and FieldCare)

Table 35: OPERATING MENU → DIAGNOSTICS → USER LIMITS

Parameters for setting user-defined limits.

Troubleshooting

Messages

List and explanation of all possible device messages (Alarm, Warning, Error).

Troubleshooting

Explanation of XD_ERROR and BLOCK_ERROR

Explanation of XD_ERROR and BLOCK_ERROR codes for troubleshooting.

Troubleshooting

Response of outputs to errors

How the device responds to different error types (Alarm, Warning, Error).

Troubleshooting

Analog Input Block

Failsafe modes and behavior of the Analog Input Block.

Appendix

Operating menu

Overview of the device's operating menu structure and navigation.

Related product manuals