EasyManua.ls Logo

Endress+Hauser Cerabar S PMP75 User Manual

Endress+Hauser Cerabar S PMP75
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BA00303P/00/EN/13.11
71139808
valid from Software version:
03.00.zz
Operating Instructions – Description of Device Functions
Cerabar S PMC71, PMP71/75
Deltabar S FMD76/77/78, PMD70/75
Deltapilot S FMB70
Process pressure / Differential pressure, Flow / Hydrostatic

Table of Contents

Other manuals for Endress+Hauser Cerabar S PMP75

Questions and Answers:

Endress+Hauser Cerabar S PMP75 Specifications

General IconGeneral
Device TypePressure transmitter
ManufacturerEndress+Hauser
Product FamilyCerabar
ModelPMP75
Measured variablePressure
Measuring principlePiezoresistive
Output signal4 to 20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Process Temperature-40 to 85 °C
Ambient temperature-40 to 85°C (-40 to +185°F)
Process connectionThread, Flange
Housing materialStainless steel
MaterialStainless steel
Protection classIP67
ApprovalsATEX, CSA, IECEx
SIL complianceSIL 2
Power Supply10.5 to 45 V DC (depending on output signal)

Summary

Operating Instructions – Description of Device Functions

Parameter Description – Local Operation and FieldCare

Measuring Mode Selection

Selecting the primary measuring mode (Pressure, Level, Flow).

Level Mode Selection

Selecting the specific level mode (Easy Pressure, Easy Height, Standard, Linearized).

Quick Setup for Pressure Measurement

Quick setup parameters for pressure measurement.

Quick Setup for Level Measurement

Quick setup parameters for level measurement.

Quick Setup for Flow Measurement

Quick setup parameters for flow measurement.

Pressure Measurement Configuration

Level Measurement Configuration

"Level Easy Pressure" Calibration

Procedure for calibrating level measurement using easy pressure mode with reference.

"Level Easy Height" Configuration

"Level Standard" Configuration

Level Linearization Entry

"Height Linearized" Level Mode

Flow Measurement Operations

Flow Type and Unit Selection

Selecting flow type (volume, mass) and corresponding units.

Parameter Descriptions – FF Configuration

Transducer Blocks

Pressure Transducer Block Details

Sensor Recalibration and Adjustment

Procedures for sensor recalibration, including highest and lowest point adjustments.

Linearization and Scaling Parameters

Configuration of linearization type and input/output scaling parameters.

Position Adjustment Procedures

Methods for adjusting the zero point, input value, or calibration offset.

Level Mode and Measurement Selection

Selection of level mode (Linear, Pressure, Height) and measured variables.

Combined Measurement and Unit Configuration

Configuration for combined level measurements and associated unit settings.

Calibration Mode and Density Settings

Configuration of calibration mode (Wet/Dry) and fluid density.

Linearization Table Entry Modes

Selection of manual or semiautomatic modes for linearization table entry.

DP Flow Transducer Block

Flow Measurement Type and Unit Selection

Selection of flow measurement type (volume, mass) and corresponding units.

Diagnostic Transducer Block Functions

Alarm Management and Response

Settings for alarm acknowledgment, reset, error types, and alarm delays.

Analog Input Block Parameters

Output Scaling and Simulation Settings

Configuring output scaling and simulation parameters for the block.

Input Scaling and Channel Assignment

Setting input scaling and assigning transducer signals to channels.

Input Linearization and Cutoff Settings

Selecting input linearization type and configuring low cutoff values.

Pressure Measurement Operations

Level Measurement Operations

"Level Easy Pressure" Calibration Procedures

Procedures for calibrating level measurement in easy pressure mode (wet and dry).

"Level Easy Height" Configuration and Calibration

Configuration and calibration procedures for Level Easy Height mode (wet and dry).

"Level Standard" Configuration Options

Configuration options for Level Standard mode, including Linear and Pressure Linearized.

Level Linearization Entry

Procedures for entering linearization tables in semiautomatic and manual modes.

"Height Linearized" Level Mode

Configuration and calibration procedures for Height Linearized level mode.

Position Adjustment Procedures

Basic Setup – Pressure Measurement

Basic Setup – Level Measurement, "Level Easy Pressure"

Output Unit and Calibration Mode Settings

Setting output units and calibration modes for easy pressure level.

Basic Setup – Level Measurement, "Level Easy Height"

Level Unit, Calibration Mode, and Density Settings

Selecting level units, calibration modes, and density units.

Basic Setup – Level Measurement, "Level Standard"

Level Mode and Custom Unit Configuration

Selecting level mode and configuring custom units for pressure.

Basic Setup – Level Measurement, "Linear" Level Mode

Calibration Mode and Density Settings

Setting calibration mode and fluid density for linear level mode.

Basic Setup – Level Measurement, "Pressure Linearized"

Basic Setup – Level Measurement, "Height Linearized"

Calibration Mode and Level Points

Setting calibration mode and level points for height linearized mode.

Extended Setup Options

Linearization Function Group – Local Operation

Linearization Function Group – FieldCare

Totalizer Setup Function Group

Process Information Group

Process Values for Pressure Measurement

Display of measured, corrected, and sensor pressure values.

Process Values for Level Measurement

Display of measured level, pressure, and sensor temperature values.

Process Values for Flow Measurement

Display of measured flow, pressure, and totalizer values.

Operation Functions

Diagnostics – Simulation Settings

Diagnostics – Messages and Alarms

Troubleshooting Guide

Understanding Device Messages

Lists all possible messages (Alarm, Warning, Error) with causes and measures.

Error Codes, Causes, and Measures

Detailed table of error codes, their causes, and recommended measures for resolution.

Response of Outputs to Errors

Defines device behavior (Alarm, Warning, Error) for output responses to detected issues.

Confirming Messages