Endress+Hauser Cerabar M PMC51 Specifications

General IconGeneral
TypeCerabar M PMC51
Measuring PrinciplePiezoresistive
Output Signal4-20 mA HART
HousingAluminum, stainless steel
ApprovalsATEX, IECEx, CSA, FM
CommunicationHART
Operating Temperature-40°C to +85°C
Ambient Temperature-40°C to +85°C
Protection ClassIP66
Electrical ConnectionCable gland
Power Supply10.5 to 45 V DC
Process ConnectionThreads, flanges, hygienic connections

Summary

Operating Instructions

Overview of documentation

Technical Information

Contains technical data for Cerabar M, Deltabar M, Deltapilot M.

Operating Instruction

Details installation, operation, commissioning, maintenance, and troubleshooting.

Brief Operating Instruction

Provides installation, wiring, operation, and commissioning steps.

Safety instructions

Designated use

Specifies the intended use for Cerabar M, Deltabar M, and Deltapilot M devices.

Installation, commissioning and operation

Details requirements for safe installation, connection, commissioning, and operation.

Operational and process safety

Discusses safety measures during configuration, testing, and servicing.

Hazardous areas (optional)

Covers safety instructions for devices used in hazardous locations.

Notes on safety conventions and icons

Explains safety symbols, warnings, cautions, and notes used in the manual.

Identification

Device designation

Information on identifying the device via its nameplate and designation.

Scope of delivery

Lists the items included in the device package.

CE mark, Declaration of Conformity

Confirms device compliance with EC Directives and safety requirements.

Registered labels

Lists registered trademarks and labels associated with the device.

Installation

Incoming acceptance and storage

Procedures for checking shipment and proper storage of the device.

Installation conditions

Information regarding necessary conditions before device installation.

Installing Cerabar M

Specific instructions for installing the Cerabar M device.

Installation instructions for devices without diaphragm seals – PMP51, PMC51

Specific installation guidance for Cerabar M models without diaphragm seals.

Installation instructions for devices with diaphragm seals – PMP55

Specific installation guidance for Cerabar M models with diaphragm seals.

Installing Deltabar M

Specific instructions for installing the Deltabar M device.

Installation position

Guidance on optimal mounting position for Deltabar M devices.

Installing Deltapilot M

Specific instructions for installing the Deltapilot M device.

General installation instructions

General guidelines for installing Deltapilot M devices.

Wiring

Connecting the device

Step-by-step guide for electrical connection of the device.

Connecting the measuring unit

Instructions for connecting the measuring unit to the device.

Shielding/potential equalization

Guidelines for proper shielding and potential equalization.

Connecting handheld terminal (DXR375/FC375)

Instructions for connecting a HART handheld terminal.

Connecting Commubox FXA195 for operation via FieldCare

Connecting the Commubox FXA195 for operation with FieldCare.

Potential equalization

Connecting devices to local potential equalization for hazardous areas.

Overvoltage protection (optional)

Information and instructions for optional overvoltage protection.

Post-connection check

Checklist to perform after completing electrical installation.

Operation

Operating options

Overview of different methods for operating the device.

Operation without operating menu

Operating the device using keys and DIP switches without a display.

Position of operating elements

Locating and function of operating keys and DIP switches.

Operation with an operating menu

Operating the device using its menu structure.

Operation concept

Explanation of user roles and their responsibilities in operating the device.

Structure of the operating menu

Details the hierarchical structure and submenus of the operating menu.

Operation with a device display (optional)

Instructions for operating the device using its optional local display.

Operation via HART handheld terminal

Using a HART handheld terminal for parameter setup and operation.

Operation via FieldCare

Using FieldCare software for device configuration and asset management.

Locking/unlocking operation

Procedures for locking and unlocking device operation.

Resetting to factory settings (reset)

How to reset device parameters to factory or order configuration settings.

Commissioning

Function check

Steps for performing post-installation and post-connection checks before commissioning.

Commissioning without an operating menu

Commissioning the device using keys without a display.

Commissioning with an operating menu

Commissioning the device using its menu structure.

Position zero adjustment

Correcting pressure shifts caused by device orientation.

Level measurement (Cerabar M and Deltapilot M)

Information and overview for level measurement tasks.

"In pressure" level selection Calibration with reference pressure (wet calibration)

Wet calibration for level measurement using pressure references.

"In pressure" level selection Calibration without reference pressure (dry calibration)

Dry calibration for level measurement without pressure references.

"In height" level selection Calibration without reference pressure (dry calibration)

Dry calibration for level measurement using height references.

Linearization

Methods for linearizing measurement data.

Pressure measurement

Procedures for calibrating pressure measurement.

Differential pressure measurement (Deltabar M)

Information and preparatory steps for differential pressure measurement.

Flow measurement (Deltabar M)

Information and preparatory steps for flow measurement.

Level measurement (Deltabar M)

Information and preparatory steps for level measurement.

Maintenance

Exterior cleaning

Instructions for cleaning the exterior of the device.

Troubleshooting

Messages

List of possible error and status messages with causes and measures.

Response of output to errors

Defines output behavior based on specific error conditions.

Repair

Information on the Endress+Hauser repair concept and general repair guidelines.

Repair of Ex-certified devices

Specific safety and procedural requirements for repairing Ex-certified devices.

Spare Parts

Guidance on how to find and order spare parts for the device.

Return

Procedures and requirements for returning a device for repair or inspection.

Disposal

Instructions for proper disposal and recycling of device components.

Software history

Details software versions and corresponding documentation for different devices.

Technical data

Appendix

Overview of operating menu

A comprehensive list of all device parameters with their locations and page references.