EasyManua.ls Logo

Endress+Hauser Cerabar S PMC71 User Manual

Endress+Hauser Cerabar S PMC71
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BA00303P/00/EN/13.11
71139808
valid from Software version:
03.00.zz
Operating Instructions – Description of Device Functions
Cerabar S PMC71, PMP71/75
Deltabar S FMD76/77/78, PMD70/75
Deltapilot S FMB70
Process pressure / Differential pressure, Flow / Hydrostatic

Table of Contents

Other manuals for Endress+Hauser Cerabar S PMC71

Questions and Answers:

Endress+Hauser Cerabar S PMC71 Specifications

General IconGeneral
BrandEndress+Hauser
ModelCerabar S PMC71
CategoryMeasuring Instruments
LanguageEnglish

Summary

Operating Instructions – Description of Device Functions

Process pressure / Differential pressure, Flow / Hydrostatic

Overview of measurement types: Process pressure, Differential pressure, Flow, and Hydrostatic measurements.

1 Notes on use

1.1 Finding parameter descriptions using ID numbers

Describes how to find parameter descriptions using their unique identification (ID) numbers.

2 Parameter description of local operation and FieldCare

3 Graphic representation of function groups

3.1 Representation via device display

Illustrates the graphical representation of function groups as displayed on the device.

4 Pressure measurement (FF configuration program)

5 Level measurement (FF configuration program)

5.1 Overview of level measurement

Provides an overview of different level measurement tasks, selection modes, and descriptions.

5.2 "Level easy pressure" level selection

5.2.1 Calibration with reference pressure – wet calibration

Details the wet calibration process for 'Level easy pressure' using reference pressure.

5.3 "Level easy height" level selection

5.3.1 Calibration with reference pressure – wet calibration

Details the wet calibration process for 'Level easy height' using reference pressure.

5.4 "Level standard" level selection, "Linear" level mode

5.4.1 Calibration with reference pressure – wet calibration

Details wet calibration for 'Level standard' with 'Linear' mode using reference pressure.

5.5 "Level standard" level selection, "Pressure linearized" level mode

5.5.1 Semiautomatic entry of the linearization table

Explains semiautomatic linearization table entry for 'Pressure linearized' level mode.

5.6 "Height linearized" level mode

5.6.1 Dry calibration and manual entry of the linearization table

Details dry calibration and manual linearization table entry for 'Height linearized' mode.

6 Flow measurement (FF configuration program)

6.1 Calibration

Describes the calibration procedure for flow measurement via local interface and FieldCare.

6.2 Totalizer

7 Parameter description (FF configuration program)

7.1 Cerabar S/Deltabar S/Deltapilot S block model

Describes the different blocks comprising the device: Resource, Transducer, and Function Blocks.

7.2 Resource Block

7.3 Transducer Blocks

7.3.1 FOUNDATION Fieldbus Transducer Blocks standard parameters

Outlines standard parameters applicable to all FOUNDATION Fieldbus Transducer Blocks.

7.3.2 Pressure Transducer Block

7.3.6 Diagnostic Transducer Block

7.4 Analog Input Block (function block)

8 Pressure measurement (via local operation and FieldCare)

9 Level measurement (via local operation and FieldCare)

9.1 Overview of level measurement

Provides an overview of different level measurement tasks, selection modes, and descriptions.

9.2 "Level easy pressure" level selection

9.3 "Level easy height" level selection

9.4 "Level standard" level selection, "Linear" level mode

9.5 "Level standard" level selection, "Pressure linearized" level mode

9.6 "Height linearized" level mode

10 Flow measurement (via local operation and FieldCare)

10.1 Calibration

Describes the calibration procedure for flow measurement via local interface and FieldCare.

10.2 Totalizer

11 Parameter description (Local operation and FieldCare)

12 Troubleshooting

12.1 Messages

Lists all possible messages (Alarm, Warning, Error) with descriptions and causes.

12.2 Response of outputs to errors

12.2.1 Analog Input Block

Explains the failsafe modes for the Analog Input Block when receiving invalid data.

13 Appendix

13.1 Operating menu

Depicts the overall menu structure and notes on its variations.