Operating Instructions
Soliwave FQR56/FDR56
Microwave barrier

Other manuals for Endress+Hauser Soliwave FDR56

Questions and Answers

  • J
    James MataAug 11, 2025
    What to do if Endress+Hauser Measuring Instruments signal strength fluctuates?
    • E
      ericksonmikeAug 11, 2025
      If you notice strong fluctuations in the signal strength of your Endress+Hauser Measuring Instruments, it could be due to a turbulent application or reflections. To resolve this, increase the signal damping.
  • S
    Scott BallardAug 17, 2025
    What to do if the yellow LED is off with uncovered path on Endress+Hauser Measuring Instruments?
    • J
      Jennifer JacksonAug 17, 2025
      If the yellow LED is off even when the path is uncovered on your Endress+Hauser Measuring Instruments, there could be several reasons: * There might be no power or the power is too low. Check the power supply. * The emitter could be defective, in which case you should replace it. * The path of rays might be covered (e.g., the window is dirty). Inspect the path of rays and clean if necessary. * The installation could be incorrect, so verify the installation. * The settings might be wrong, so review the settings.
  • J
    Janice LittleAug 23, 2025
    Why is the yellow LED on with covered path on Endress+Hauser Measuring Instruments?
    • A
      anneshawAug 25, 2025
      If the yellow LED remains on even when the path is covered on your Endress+Hauser Measuring Instruments, it may be because the receiver is defective (in which case, replace the receiver) or the attenuation of the product is too low (adjust the sensitivity).
  • H
    Heather CameronAug 28, 2025
    Why is the yellow LED off with an uncovered path on my Endress+Hauser Industrial Equipment?
    • J
      Jennifer JensenAug 29, 2025
      If the yellow LED is off even when the path is uncovered on your Endress+Hauser Industrial Equipment, there are several potential causes: * **No or low power:** Check the power supply to ensure it is adequate. * **Defective emitter:** The emitter may need replacing. * **Obstructed path:** Inspect the path for obstructions and clean if necessary. * **Incorrect installation:** Verify the installation is correct. * **Incorrect setup:** Ensure the device is set up properly.
  • C
    carla51Sep 3, 2025
    What to do if there is strong fluctuation of signal strength in Endress+Hauser Industrial Equipment?
    • J
      James PerkinsSep 3, 2025
      If you observe significant fluctuations in signal strength with your Endress+Hauser Industrial Equipment, the cause may be turbulent application conditions or reflections. To address this, increase signal damping.

Endress+Hauser Soliwave FDR56 Specifications

General IconGeneral
Communication ProtocolHART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply24 V DC
ApplicationLevel measurement of liquids and solids
Process Temperature-40°C to +150°C
Output Signal4…20mA HART
International explosion protection certificatesATEX, IECEx
Housing MaterialAluminum
Antenna MaterialPTFE
Protection ClassIP66/IP68
MaterialAluminum, PTFE