General IconGeneral
Device TypeDifferential Pressure Transmitter
Process Pressure Limitup to 400 bar (5800 psi)
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Housing MaterialAluminum, stainless steel
ApplicationLevel, volume or mass measurement in liquids
Measuring Rangeup to 40 bar (580 psi)
Process Temperature-40 to 120 °C (-40 to 248 °F)
Accuracy±0.075%
Output Signal4...20 mA HART
Power Supply10.5 to 45 V DC
Sensor TypePiezoresistive
Long-term stability±0.1% of URL/year
Reference accuracy±0.075% of span
Process ConnectionThreaded and flange connections
Protection ClassIP66
Material316L