Soliwave FQR56/FDR56
Operating options
32
Endress+Hauser
7�2 Structure and function of the operating menu
7�2�1 FDR56
0
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
...
...
Selection of the function
Display of the selected function
aerapprox.2seconds
Display of the function value
(example: hysteresis function 5)
18 OperationoftheFDR56
Procedure of parametrization:
Selectanyfunction(overview→54)
→Encoding switch 1 to F
→Thedisplayshowstheselectedfunctionfortwoseconds.
Example function 3:
Setting the selected function
Example: Function 3 (manual setup on free path)
→Youcanusethetwooperatingbuttons
and to increase or decrease the sensitivity
in 10% increments.
or
→ →
→ →
... ...
Theconguredvalueisstoredassoonasthefunctionisswitched.Thevaluecanbe
displayedagainatanytimebyselectingthecorrespondingparameterconguration
function and changed if necessary.
Onceparametercongurationiscomplete(i.e.oncethemicrowavebarrierhasbeen
adaptedtothemediuminquestion),theencodingswitchmustbereturnedtothe"0"
position. The Soliwave FDR56 is now ready for operation.