12
*A maximum water temperature of 55°C can be reached by the heat pump without using auxiliary
heaters. However, if the target temperature is set between 55°C and 75°C the electric heater will
be activated above 55°C to reach this temperature.
Param-
eter
Description Range Default Remark
15
Heat pump auto restart mode
(Off = 0; On = 1)
0 / 1 1 Adjustable
16
Starting temperature for defrosting
evaporator
-9 ~ 10 °C 4°C Do not change
17 Beeper (Off = 0; On = 1) 0 / 1 1 Adjustable
18 Disinfecting cycle (Off = 0; On = 1) 0 / 1 1 Do not change
19
Geyser temperature measurement
probe offset
-10 ~ 10°C 3°C Do not change
20
Automatic geyser temperature
measurement probe offset
0 (fixed) / 1
(calculated)
0 Do not change
21 EEV setting 0 - 5 0 - 5
See remarks at
the end of the
table
22
HP temperature measurement
probe offset
-5 ~ 5 °C 3 °C Do not change
A Water temperature -9 ~ 90°C Reading
Temperature
output
B Evaporator coil temperature -9 ~ 90°C Reading
Temperature
output
C Compressor discharge temperature 0 ~ 127°C Reading
Temperature
output
D Ambient temperature -9 ~ 90°C Reading
Temperature
output
E
Heat pump return water
temperature
-9 ~ 90°C Reading
Temperature
output
F
Electronic expansion valve
operating parameter
0 ~ 50 Reading
Valve open
output