L2062 Rev. B 04/98
IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If any shipping damage is found, notify
carrier at once. Shipping damage is NOT covered by warranty. The carrier is responsible for all
repair or replacement costs resulting from damage in shipment.
CONTENTS
SAFETY INFORMATION
To avoid personal injury or property damage during system operation, read and follow all
CAUTIONS, WARNINGS, and INSTRUCTIONS included with, or attached to, each product. ENERPAC
CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY RESULTING FROM UNSAFE USE OF PRODUCT,
LACK OF MAINTENANCE OR INCORRECT PRODUCT AND SYSTEM APPLICATION
. Contact Enerpac
when in doubt as to safety precautions, or applications.
A WARNING
The system operating pressure must not exceed the pressure rating of the
lowest rated component in the system. Install pressure gauges in the
system to monitor operating pressure.
A WARNING
To avoid personal injury, do not use electric pumps in an explosive
atmosphere. Adhere to all local and national electrical codes.
A WARNING
These pumps have factory-adjusted internal relief valves which must not
be repaired or adjusted except by qualified hydraulic technicians.
A WARNING
Make sure that all system components are protected from external
sources of damage, such as excessive heat, flame, moving machine parts,
sharp edges, and corrosive chemicals.
s CAUTION
Check specifications and motor plate data. Use of an incorrect power
source will damage the motor.
®
A UNIT OF APPLIED POWER INC.
Instruction Sheet
1
/
2
HP Portable Electric Pumps
ENGLISH . . . . . . . . . . . . . . 1-7
DEUTSCH . . . . . . . . . . . . 8-14
FRANCAIS . . . . . . . . . . . 15-21
ESPAÑOL . . . . . . . . . . . . 22-28
ITALIANO . . . . . . . . . . . 29-35
NEDERLANDS . . . . . . . . . 36-42

Other manuals for Enerpac PUJ-1201B

Questions and Answers:

Enerpac PUJ-1201B Specifications

General IconGeneral
SeriesPUJ
Usable Oil Capacity (in3)120
Maximum Operating Pressure (bar)700
Usable Oil Capacity (L)2.0
Maximum Operating Pressure (psi)10000

Summary

IMPORTANT RECEIVING INSTRUCTIONS

SAFETY INFORMATION

SPECIFICATIONS

INSTALLATION

Hydraulic Connections

Use Teflon tape on threads, leaving the first complete thread free of tape to prevent shedding into the hydraulic system.

Valve Mounting

Adding Oil

OPERATION

Switch Operation

Details the three-position switch for pump activation and control via pendant switch.

Pump Control Valve

Explains the 3-way, 2-position valve for directing hydraulic fluid output or return.

Thermal Relay

Air Removal

RELIEF VALVE ADJUSTMENT

Adjusting the Relief Valve Setting

Steps to install a gauge, adjust the relief valve screw, and verify the setting for desired pressure.

MAINTENANCE

Checking the Oil Level

Check oil level every 40 hours of operation and add Enerpac hydraulic oil as needed.

Changing the Oil

Drain reservoir every 100 hours, refill with new hydraulic oil, capacity depends on model.

Cleaning the Reservoir

Remove reservoir for cleaning with solvent, clean pick-up screens, and re-assemble with new gasket.

TROUBLESHOOTING