Enerpac Z-Class - Pump Type 10 Automode Notes

Enerpac Z-Class
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Table 3, Z-Class Pump Model Matrix • Firmware 7.x • Pump Types 1, 2, 3, 6, 8 and 10
Pump
Type.
Pump
type
Pump type
code
pendant
Item
Motor
On/Off
Arrow
down
Arrow up
Motor
On/Off
What happens when _____ button is pushed in
normal operation mode (“READY” is displayed on LCD)
Pendant Button
LCD Panel
Button
Action when HI_PRESS
(SET_PRESS) value is
reached
Max value
for HI_PRESS
Additional comments
valve
Action when LO_PRESS
value is reached
Max value for LO_PRESS
foot
switch
10
Manual
Momen-
tary
Pump
ZxxxxxWx
3-button
none
Motor & Fan
(if attached)
Solenoid A
Solenoid B
Momentary
On
(no toggle)
no
change
no
change
no change
off
no change
momentary on
Note: Motor may
be on or off
(advance)
off
toggle
on/off
(see note 1)
off
off
when HI_PRESS is reached
only the valve shuts off,
motor continues running
off
off
10,500 psi
Similar to pump No. 6 execpt that LOCAL MODE
is the default at start-up. Pendant buttons are
disabled.
(See Note 2)
VE33 / VE43
none
na
on
off
na
50 psi less than HI_PRESS current
value. 0 means LO_PRESS is
turned off
na
Option
momentary
on
Note: Motor
may be
on or off
(retract)
Operation with Automode ON
Pumps Equipped with Pressure Transducer Option Only
Notes - Pump Type 10:
1. if Automode is OFF, motor is momentary on (no toggle).
2. If Automode is OFF, solenoids can be operated manually when motor is off or on.
Table 4, Z-Class Pump Model Matrix • Firmware 7.x • Pump Types 1, 2, 3, 6, 8 and 10
(Continued from previous page)