EasyManuals Logo

enphase Enpower User Manual

enphase Enpower
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Enpower smart switch installation and operation
© 2020 Enphase Energy Inc. All rights reserved. 141-00046-01
18
F. Use the included stowed conductors, as labeled, to wire the circuit breaker(s) for the Encharge
batteries, Enphase Combiner, and generator (reserved for future use¹) as needed. The stowed
conductors are provided with crimped-on ferrules with end caps to prevent accidental contact.
Remove the conductor end caps as needed.
G. Torque the breaker connections as listed on the previous page and in the conductor table on the
unit.
H. After all conductors are connected and secured, check that there are no exposed conductors or
stray wires.
I. Gently arrange all the conductors and connectors inside the cabinet.
DANGER! Risk of electric shock. The system is not ready to be energized! Do not close any
circuit breaker yet.
NOTE: The polarity of L1 and L2 is swapped inside Eaton CSR series main breakers.
Installers should follow L1 and L2 on the following image when installing consumption CTs.
Reserved for
future use
Reserved for
future use

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the enphase Enpower and is the answer not in the manual?

enphase Enpower Specifications

General IconGeneral
Frequency60 Hz
Enclosure RatingNEMA type 3R, outdoor
ComplianceUL 1741
Input Voltage120/240V
Output Voltage120/240V
Maximum Continuous Power7.6 kW
Humidity0-100%
CommunicationWi-Fi