EasyManua.ls Logo

Envertech EVT360 Quick Installation Guide

Envertech EVT360
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Envertech EVT300 & EVT360 + EVB300 Quick Installation Guide
Please read and follow the safety and installation
instructions below. You can find and download the
instructions or other technical documents on our
website: www.envertec.com
.
Components
Microinverter
Monitoring Device
Monitoring APP
EVT300 & EVT360
EnverBridge
EnverView
PV
Module
60-cell / 72-cell module
AC
Extension
Cable
(Optional)
To connect the AC side
to the grid.
Three-wire cable:
AWG12 or above.
AC End
Cap
To seal the end of
unused AC cable.
Note: EnverView App version should be 2.6 and above and EVB300 firmware
version should be EVB300-E-N-001-14 and above.
Envertech EVT300 & EVT360 Microinverter Installation
1. Mount microinverters onto the rack
Mark out the estimated center of each PV module on the rack to facilitate locating
microinverters..
Mount all microinvertes under modules to avoid rain and sun, with the trademark
facing downward.
Please make sure that there are less than 20 units of EVT300, or 16 units of
EVT360 in each branch(12AWG).
2. Grounding
Microinverters and modules must be connected to the grounding conductor in
accordance with national standards.
Fix the grounding wire with screws to the microinverters grounding hole, so that
the grounding of microinverters can be realized.
3. Connect microinverter AC cables serially
Connect the AC connectors on both sides of microinverters in a hand-in-hand way.
4. Fastern AC cables
Fasten AC cables and grounding cables to the rack with cable ties.
5. Seal the unused connector of AC cable
Insert the end cap directly into the connector on the unused end, and check if it is
inserted in place.
6. Connect AC cable to the junction box
Connect AC cable to the input of the junction box.
7. Mount EnverBridge
Take out the power cord and connect it to the EVB300, Screw on the antenna. Wait 3
minutes till the EVB300 green light blink, you can start the operation after booting
EVB300.
1) Installation
Option 1: Ethernet Mode
Fix EVB300 at proper position in or
close to the distribution box;
2. Run the RJ45 cable and connect the
EVB300 to your router;
3. Put the EVB300 plug into the socket.
Option 2: Wireless mode
Fix EVB300
at proper position in or
close to the distribution box within the
range Wi-Fi signal.
Turn off the air switch and connect
EVB300’ s power cable to the air switch.
2) Wi-Fi configuration setting
a) Connect network whose name is as same as your monitor’s SN in your
cellphone.
b) Open EnverView and click Wi-Fi Setting.
Installation could only be implemented when the system is
disconnected from the grid, and the solar panel has been covered
or disconnected.

Other manuals for Envertech EVT360

Question and Answer IconNeed help?

Do you have a question about the Envertech EVT360 and is the answer not in the manual?

Envertech EVT360 Specifications

General IconGeneral
BrandEnvertech
ModelEVT360
CategoryInverter
LanguageEnglish

Related product manuals