12
Installation and operation from the left
To install and operate the unit from the left, the front
and rear panels must be exchanged. To do this, lay the
unit on the side opposite the operating side.
Loosen and remove the two screws holding the base
to the unit from the underside of the base. Then pull the
front panel down and out of the side housing
components (as was done with the rear panel) (Fig. 7)
and push it back into the housing frame on the opposite
side (Fig. 8).
Commissioning and initial operation
The sauna heater must never be operated with an
empty stone grate. Ensure prior to initial operation
that no objects have been left lying on the sauna
heater.
This knob is used to set the heating period up to a
maximum of 4 hours. Turn the knob to the desired
heating time and the heater begins to heat up.
Nach Ablauf der eingestellten Zeit schaltet das Sau-
naheizgerät automatisch ab.
This knob is used to set the desired sauna
temperature. Please remember that temperature is
controlled near the temperature sensors and that
temperatures will vary within the sauna cabin.
Temperature is controlled with a range between 30° C
and 110° C. Ordinarily, sauna bathing temperature in
the area around the upper recliner bench will be
between 80° C and 90° C.
Safety temperature limiter
The sauna heating unit is equipped with a safety
temperature limiter (STL), which automatically shuts
the heater off when the sauna overheats. In this case,
the system must be checked by a specialist. The STL
must then be reset before the heater can be operated
again.
Turn the base 180° and refasten it to the housing. The
eye plates on the side must hold the front panel firmly
in place.
Fig. 7