9
Dear customer:
You have purchased a high-quality sauna heater that
will give you years of sauna bathing pleasure. This
sauna heating unit has been designed in conformity
with the latest European safety standards, tested and
manufactured at our production facility in accordance
with quality standard EN DIN ISO 9001.
This detailed Installation and Operating Guide has
been prepared for your information. Please give special
attention to the Special Instructions and information
regarding electrical connections and wiring.
We wish you many hours of pleasant, stimulating
sauna bathing.
Prior to installation, please check to ensure that the
sauna heating unit has been delivered to you in
proper condition. Damage incurred in transport should
be reported immediately to the shipping agent or the
supplier who arranged delivery to you.
The delivery package includes the following
components:
1 sauna heater
1 accessory bag, including: 4 tension-plate screws
1 set of sauna stones
General instructions
Please note that optimum sauna climate conditions
can be achieved only if the cabin ventilation (fresh air
and exhaust) system, the sauna heater and the control
unit are designed and set to work efficiently in
combination.
Please observe the instructions and information
provided by your sauna supplier.
Sauna heating units heat your sauna cabin with
warmed convection air. Fresh air drawn by suction
pressure through the fresh-air inlet is heated, rises
upward (convection) and is then circulated within the
cabin. Some of the consumed air is forced out of the
cabin through the exhaust outlet. This process
produces a typical sauna climate, with temperatures
of approximately 110° C immediately below the ceiling
and a temperature gradient that produces low
temperatures of approximately 30-40° C at floor level.
Thus it is not unusual for the temperature sensor
above the heater to register 110° C, while the
thermometer mounted on the sauna wall
approximately 20-25 cm below the cabin ceiling shows
only 85° C. Ordinarily, sauna temperatures range
between 80° C and 90° C at the level of the upper
recliner bench at the maximum temperature setting.
Please remember that temperatures are always at
their highest just above the sauna heating unit and
ensure that temperature sensors and safety limiters
are mounted there.
When the unit is heated up for the first time, evaporation
of residual substances from the production process
may cause slight odors. The cabin should be aired out
thoroughly before you begin your sauna bath.
Sample wiring diagram for a sauna system
Important! The ground lead (N) must always be connected
Fig. 1
Temperature
limiter
blue 1,5
2
blue 1,5
2
blue 1,5
2
blue 1,5
2
Heating coil
Heating coil
Double buffer
Double buffer
Timer
b/w 1.5
2
b/w 1.5
2
b/w 1.5
2
b/w 1.5
2
b/w 1.5
2
Main power
grid
Main power
connection
Cr cable
y