OPTIC CONFIGURATION
e EOTECH Holographic Weapon Sight (HWS)
product line has two dierent heights above the rail
based on user preference. For this reason, the mag-
nier does not come preassembled to the mount.
It is user congurable based on the specic model
HWS it will be mounted behind. e 7mm riser,
included, may be required to align the magnier
optical axis with the sight. Only HWS models with
side buttons or quick detach levers require the use of
the riser. For all other HWS models, the riser should
not be used.
e magnier system can be congured to switch to the le or to the right based on shooting preference.
Typically, right handed shooters prefer the mount to switch to the le, and le handed shooters to the right.
To congure your HWS you will need a screwdriver (not included). If the spacer is not used, the shorter
screws should be selected. e longer screws are used with the spacer only. If the spacer is being used, place
the spacer on the optic mounting interface. Open the STS mount. Position the mount on the optic mount
interface (or riser) so it opens either to the le or right (based on preference). Insert each screw through the
components, and tighten securely.
INTRODUCTION
ank you for purchasing EOTECHs new Generation III 3X
magnier. ese magniers oer users of the Holographic
Weapon Sight (all models) the additional advantage of vastly
improved target recognition and increased lethality at medium
range distances. e new Switch to Side (STS) mount allows
the user the ability to engage the enemy with condence in a
Close Quarters Battle (CQB) situation or at distances out to 600
meters or more. is user manual describes the features of the
EOTECH Magniers and provides information on their use and maintenance. Please read the instructions
carefully before mounting and using the magniers. Always practice proper rearm safety.
USERS MANUAL FOR G33™
For use with G33 Magniers
or HHS Systems
e G33 is controlled under the Export Administration Regulations (EAR) ECCN 0A987, and may not be exported to a
foreign person, either in the U.S. or abroad, without a license or exception from the U.S. Department of Commerce
SPECIFICATIONS:
G33 3x Magnier
Magnication Fixed: 3X
Eye Relief: 2.2” (55.8mm)
Field of View: 7.3 degrees
Length: 3.9” (99mm)
Width: 2.2” (55.9mm)
Height: 3.3” (83.9mm) with spacer
Weight: 11.2oz (317.5g) with mount
Water-Resistant: 33 . (10m)
Sealing: Fog-resistant internal optics
Retrots to all HWS models with 7mm riser
Finish: Non reective / Rubber coated
Optical Axis Adjustment: Internal adjustment
Switch Orientation: Ambidextrous mount Flip Orientation to
allow le or right ip
Rail Interface: 1” Weaver or MIL-STD-1913 with Quick
Detach lock
Magnier Interface: User congurable height with quick
detach mount
Included:
• 3x Magnier • Switch to Side (STS) Mount• 7mm Riser • 4 Screws
BASIC OPERATION
e G33 magnier is designed to be used behind an EOTECH Holographic Weapon Sight (HWS). e magni-
er can be mounted directly behind the HWS. Simply switch the magnier out of the way and operate the
sight. When used with HWS models 518, 558, 556, 517, EXPS or 516 HWS (with side button interface) the
user can easily operate the sight even with the magnier in the locked position.
Positioning the Reticle:
Once the magnier is installed properly behind the HWS, it may be necessary to re-zero the sight. is may
be due to the shooters ability to see the target and Point of Impact (POI) more accurately than without the
magnier. Re-zeroing the sight will prevent a perceived shi in POI when going from no magnication to
magnication.
Aer zeroing or re-zeroing the sight, it may be necessary to reposition the reticle image into the center of the
magnier window. is is aesthetic in nature and has no aect on the sights zero. Turn the horizontal and
vertical adjustments on the top or side of
the magnier by hand, with a coin or a
at head screwdriver to reposition reticle
to the desired position.
Switch operation:
To switch the magnier to the side,
simply push the optic to the right or le,
depending on how it is mounted. To close
the mount, push the magnier back into
its original position until a hard stop is
achieved.
ADJUSTABLE DIOPTER
e G33 optic includes an adjustable diopter that allows the user to customize
the focus to their particular vision. is feature ensures a crisp, clean aiming
dot for more precision and shot placement. To adjust, simply grasp the diopter
with the thumb and fore nger and turn either clockwise or counter-clockwise
until a clear sight picture is achieved.
M1957 Rev B
Question and Answer IconNeed help?

Do you have a question about the EOTech G33 and is the answer not in the manual?

EOTech G33 Specifications

General IconGeneral
Magnification3x
Eye Relief2.2 inches
MaterialAluminum
FinishMatte black
Weight11.2 oz
Mount TypeMIL-STD-1913
CompatibilityEOTech HWS models
Field of View7.3 degrees
Length3.9 inches

Summary

Introduction to the G33 Magnifier

Included Items

Lists the items included with the G33 magnifier.

Optic Configuration

Explains how to configure the magnifier with HWS models and riser.

G33 Magnifier Specifications and Compatibility

G33 Magnifier Specifications

Details physical and performance characteristics of the G33 magnifier.

Compatibility

Specifies compatibility with HWS models and the 7mm riser.

Basic Operation of the G33 Magnifier

Positioning the Reticle

Explains how to re-zero the sight after magnifier installation.

Adjustable Diopter

Describes how to adjust the diopter for a clear aiming dot.

Switch Operation

Details how to switch the magnifier to the side.

Installation and Adjustment

Rail Mount Adjustment

Explains how to adjust the mount for a proper fit on the rail.

Maintenance and Warnings

Cleaning and Care

Provides instructions for cleaning the magnifier's housing and lenses.

Disassembly Warning

Warns against disassembling the magnifier due to nitrogen purging and warranty void.

EOTECH Warranty Information

Warranty Exclusions

Lists conditions and situations not covered by the EOTECH warranty.

Factory Contacts

Provides contact information for product registration, service, and support.