EasyManua.ls Logo

Epiroc EC150T - Applications; Guarantee; Removing the Packaging; Scope of Delivery

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety and operating instructions
20 © Construction Tools GmbH | 33905146 01 | 2019-09-05
Original Instructions
3.4 Applications
Field Type of application
General construction work Trenchwork for utilities,
foundation work
Demolition Heavily reinforced con-
crete, demolition of power
stations and bridges
Rock mining/breaking Primary breaking
Secondary breaking,
bench levelling foundation
work
3.5 Guarantee
The guarantee or product liability will be invalidated by
the following:
Use other than intended
Maintenance work not being carried out or being
carried out incorrectly
The use of incorrect consumables
The use of non-approved parts
Damage due to wear
Damage due to improper storage
Changes not carried out by or in consultation with
the manufacturer
3.6 Removing the packaging
n
Remove all the packaging material.
n
Dispose of it in accordance with the applicable provi-
sions.
n
Check that the delivery is complete.
n
Check the delivery for visual damage.
n
If any defects are found, consult the Epiroc Customer
Center / dealer in your area.
3.7 Scope of delivery
The hydraulic breaker is delivered complete with:
Hydraulic breaker
Test gauge lower wear bush
Safety and Operating instructions
Spare parts list
EC Declaration of Conformity
Accessories as ordered:
Working tool
Hoses
Service box
Special accessories as ordered:
e.g. adapter plate with Allen screws and pairs of lock
washers
e.g. base plate to construct an adapter plate with
Allen screws and pairs of lock washers
e.g. hydraulic fittings for the carrier
e.g. piston retainer
e.g. calliper upper wear bush

Table of Contents

Related product manuals