38
Function Command
Epson Web
Control Setting
Availability
Setting Value/Response Value
Quick Corner Coordinate
Settings/Acquire settings
(based on image projection
area)
QCS x1 x2 x3 x4 x5 x6 x7 x8 ✔ -
Parameter x1-x8: 0 to 9999
Specify in the order: top left (x, y), top right (x,y),
bottom right (x, y), bottom left (x, y)
QCS? ✔ -
Return code 0 to 9999
Coordinates (x, y) for 4 points are divided into 4 lines
and responded
Quick Corner Vector Settings QCV x1 x2 x3 x4 x5 x6 x7 x8 ✔ -
Parameter x1-x8: 0 to 99
Specify in the order: top left (x, y), top right (x,y),
bottom right (x, y), bottom left (x, y)
Quick Corner Coordinate Shift QCMV control direction
movement
✔ -
Parameter control: QC control location specifications
01: Top left control
02: Top right control
03: Bottom right control
04: Bottom left control
INIT (settings only)
direction: Direction specifications
01: Move up
02: Move down
03: Move left
04: Move right
movement: Amount of movement specifications
Only INC is enabled (settings only)
Keystone/screen correction
method settings/acquisition
CORRECTMET x1 ✔ -
CORRECTMET? ✔ -
Parameter/Return code 00: Off
01: H/V-Keystone
02: Quick Corner correction
03: Point Correction
06: Arc Correction
Geometry Correction
Load Memory
POPGC x1 ✔ -
Parameter 01: Memory 1
02: Memory 2
03: Memory 3
Geometry Correction
Save Memory
PUSHGC x1 ✔ -
Parameter 01: Memory 1
02: Memory 2
03: Memory 3
Geometry Correction
Erase Memory
ERASEGC x1 ✔ -
Parameter 00: ALL (Geometry Correction Reset Memory Settings)
01: Memory 1
02: Memory 2
03: Memory 3
Geometry Correction
Rename/Acquire Memory
NAMEGC x1 x2 ✔ -
Parameter x1 Memory No.
01: Memory 1
02: Memory 2
03: Memory 3
x2 Custom name (ASCII code)
NAMEGC? x1 ✔ -
Parameter Same as first parameter for NAMEGC
Return code Same as second parameter for NAMEGC