EH-TW8000/TW9000/TW9000W Disassembly and Assembly CONFIDENTIAL
SEIKO EPSON 110 Revision A
3.3.19 Filter Board Unit
1. Remove the Air Filter. (p.64)
2. Remove the Lamp. (p.64)
3. Remove the Rear Case. (p.66)
4. Remove the Front Case. (p.67)
5. Remove the Upper Case. (p.68)
6. Remove the MA Board (assembly). (p.70)
7. Remove the Lens Shutter. (p.77)
8. Remove the Optical Engine (assembly). (p.78)
9. Remove the Lamp Fan (assembly). (p.84)
10. Remove the EX Duct (assembly). (p.92)
11. Remove the Inner EX Duct. (p.97)
12. Remove the Power Supply (assembly). (p.103)
13. Remove the Ballast (assembly). (p.108)
14. Disconnect connector (1) and (2) of the AC Cable from the Filter Board Unit.
15. Remove the screw ( ), and remove the Filter Board Unit.
16. Remove the screw ( ), and remove the Filter Board Insulation Sheet.
Figure 3-43.
Standard Operation Time 26 Min.
This part is designated as the Safety Device. When removing/
replacing the part for repair, be sure to refer to ā€œ3.4 Safety Check
after Servicing (p.113)ā€. According to the instructions in it,
handle the part and perform the procedure after servicing.
Filter Board Unit
Filter Board
Insulation Sheet
Connector (1)/(2)
of AC Cable
C.C.SCREW,3X4,F/ZN-3C

Table of Contents