Auto-Level stops mid-
cycle
Charge chassis and/or coach batteries
Excessive vehicle motion during
leveling sequence
Damaged or defective Controller
Check and change as needed
Damaged or defective Keypad or
Controller harness
Jack LED's on keypad
stay on
Defective pressure switch or wiring
Trace and repair or replace
Defective Keypad, Controller, or
Pump harness
Trace and repair or replace
Defective Keypad or Controller
Low system pressure caused by fluid
leak or low fluid level
Correct leak or fluid level
Hydraulic pump
inoperative
Charge chassis and/or coach batteries
Blown fuse or breaker at fuse panel
Replace fuse or reset breaker
Faulty electrial connection
Defective pump motor or solenoid
Jack(s) bleed down from
leveled or stowed
position
Jack(s) are jerky when
retracting
Check fluid level and add
Jack(s) will not retract
from extended position
Low battery voltage at pump
Charge chassis and/or coach batteries
Low battery voltage or poor ground
Charge chassis and/or coach batteries
and ensure proper grounding
Damaged/defective harness from Keypad
to Controller or Controller to pump
Check fluid level and add
Defective pump motor or solenoid
If your problem is not listed, call Equalizer Systems at (800) 846-9659
Prior Authorization for warranty is required