EasyManua.ls Logo

EQUATION EQ2-30L - Troubleshooting Guide; User Checks for No Hot Water

EQUATION EQ2-30L
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96
TROUBLESHOOTING GUIDE
EN
1 SEE THE TROUBLESHOOTING TABLES
NO HOT WATER
I - To be checked by the user:
- Check the supply indicator
is on
- The knob is not adjusted in frost-free mode
- Check that one of the protection devices has not dropped (circuit-breaker) or replace fuse
If the steps in point I are verified, and the problem is not resolved, proceed as follows:
-
Caution!
The following operations must be carried out only by a qualified
professional.
A multimeter must be used to measure the voltages. It is dangerous to use a tester screwdriver
since it is not sufficiently reliable to check whether or not the voltage is present.
II - Check at every stage that the device is turned off, using a voltage checker.
- Turn off power and check that it is off on the appliance’s mains connection to the
building power.
- Check that the thermal cut-off (see diagram 3 page 104) has not tripped by pressing
the small round button in the centre.
If the thermal cut-off has not tripped, carry out the following steps:
III - Measure the voltage with a multimeter at each of the following points:
1
2
3
EN

Related product manuals