The unit is designed to be bonded to the underside of ¾” thick granite countertop
with NSF grade sealant. It should never be mounted to a steel table. The orientation
of the base unit when installed should be such that the filter is accessible to be
removed for cleaning (generally, removed side-to-side). The mounting screws that
secure the induction warmer body to the frame should be positioned front to back
when installed so as to be accessible. It is essential that the induction ready pan be
placed directly over the induction coil. To this end, a marking should be made on the
countertop so the user will know where to place the pan. The granite can be lightly
scored with a “+” in the exact center of the coil, or with whatever marking the user
prefers so the dimension and positioning of the coil under the countertop is known.
In this regard, the installation site should be marked so that the center of the coil and
the surface marking are positioned correctly during the attachment process.
The mounting frame should be removed from the unit by removing the three screws
each, on the two opposite sides of the frame. The dimension of the mounting frame
is 13-3/8” by 13-3/8”. Once the frame has been detached, the NSF sealant can be
applied to the frame, and the frame mounted to the underside of the granite by
pressing firmly and holding in place until set in accordance with the manufacturer’s
instructions.
Once the sealant has completely dried and bonded the frame to the counter, the
base unit can be reattached to the frame by installing the three screws on each side,
the unit plugged in, and the fresh air line (if desired) can be attached.
The separate control panel will need to be mounted. The panel can be mounted
horizontally in the countertop, or vertically in the face of the counter in the apron if
the countertop supports this method.
The cutout dimension for the separate control panel is 6-3/8” x 1-7/8. Maximum
distance from the base unit is determined by the length of the included ribbon cable.
Carefully place the unit into the opening to check fit. If any adjustments to the
opening size are necessary, make them before proceeding to the next step. Apply
a bead of NSF approved sealant around the underside edge of the remote panel,
pass the ribbon cable through the opening and then press the remote panel firmly
into position. Finally, connect the ribbon cable to the base unit.