8. OPERATION INSTRUCTIONS
On/off switch (11)
Pulling the red on/off switch up will start the compressor engine. Pushing it down will stop the
engine. (image B)
Quick coupling (7)
Connect:
Put the plug of your hose directly into the coupling untill you hear a clicking sound.
Disconnect:
Pull back the sleeve of the quick coupling and pull out the plug.
Adjusting the pressure
Use the pressure regulator (6) to adjust the pressure on the gauge (8). This will regulate the pressure
coming out of the working pressure valve (7).
The second gauge (13) displays the pressure in the tank. The tank pressure comes out of the tank
pressure valve (15).
Pressure valve (9)
The pressure valve is adjusted by the factory. It will start the engine at aprox. 6 bar and shut it off
at aprox. 8 bar.
Overload switch (18)
To prevent overheating the overload switch (image O) will engage automatically. If that happens, let
the compressor cool down for a few minutes before pushing the switch back in.