ERBOTOM ICC 350
Instruction manual
08.00
ERBE

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Erbe ERBOTOM ICC 350 and is the answer not in the manual?

Erbe ERBOTOM ICC 350 Specifications

General IconGeneral
BrandErbe
ModelERBOTOM ICC 350
CategoryMedical Equipment
LanguageEnglish

Summary

Introduction to the ERBOTOM ICC 350

Intended Purpose and Scope

Describes the unit's purpose and application range.

Manual Usage Guide

Provides instructions on how to effectively use this manual.

Understanding Safety Instructions

Explains the meaning of safety symbols and warnings.

Initial Operation and Setup

Pre-Operation Checklist

Emphasizes careful reading of the manual before initial use.

Essential Initial Operation Steps

Outlines key procedures for safe first-time operation.

High-Frequency Surgery Risks and Safety

Unintentional Thermal Tissue Damage

Details risks of unintended heat application to tissue.

HF Leakage Current Hazards

Explains tissue damage risks from HF leakage currents.

Unintentional HF Generator Activation

Covers causes and prevention of accidental HF generator activation.

Risks of Inappropriate HF Application

Discusses tissue damage from incorrect HF current usage.

Neutral Electrode Application Risks

Highlights dangers from improper neutral electrode placement.

Risks from Unsuitable Accessories

Covers hazards associated with non-compliant or faulty accessories.

Inattentiveness and Output Error Risks

Addresses hazards from careless handling and unit output errors.

Flammable Substance Ignition Risks

Warns about ignition risks with flammable materials.

Hot Electrode Burns and Electric Shock

Details burn risks from electrodes and electric shock hazards.

Nerve, Muscle Stimulation, and Pacemakers

Discusses stimulation risks and pacemaker interactions.

Explosion Hazards and Electronic Interference

Addresses explosion risks and potential interference with other equipment.

Description of the High-Frequency Surgical Unit

General Unit Overview

Provides a general introduction to the unit's capabilities.

Auto Cut and High Cut Modes

Details automatic voltage and arc control cutting modes.

Power Limitation and Cutting Modes

Explains power limitation, PPS, and cutting mode options.

Specialized Cutting and Coagulation Modes

Describes Endo Cut, Soft, Forced, Spray, and Bipolar coagulation.

Activation Methods and Programmability

Explains activation via footswitch/Auto Start and front panel programmability.

Controls and Indicators Overview

Power Switch and Function Fields

Describes the power switch and main function field areas.

Function Field Specifics

Auto Cut Function Field Details

Explains settings and activation for the Auto Cut function field.

Auto Coag 1 Function Field Details

Explains settings and activation for the Auto Coag 1 function field.

Auto Coag 2 Function Field Details

Explains settings and activation for the Auto Coag 2 function field.

Auto Bipolar Function Field Details

Explains settings and activation for the Auto Bipolar function field.

Working with Unit Programs

Program Storage and Management

Details the unit's 11 memory locations for settings.

Program 'b' for Bipolar Operations

Describes settings and parameters for bipolar cutting/coagulation.

Program 'E' for Endo Cut

Details settings and parameters for the Endo Cut mode.

Connecting Sockets and Ports

Neutral Electrode and CUT/COAG Sockets

Describes connections for neutral electrodes and CUT/COAG function fields.

Bipolar, Footswitch, and Safety Connections

Details AUTO BIPOLAR socket, footswitch connections, and safety field.

Ancillary Connections and Controls

Covers potential equalization, volume, power, and fuses.

Detailed Safety Features

Low and High Frequency Leakage Monitoring

Explains the function of LF and HF leakage current monitors.

Output Error and Time Limit Monitoring

Describes monitoring for unit output errors and activation time limits.

Customizing Maximum Time Limits

Provides instructions for adapting the maximum time limit per mode.

NESSY and Operating Error Protection

Details the Neutral Electrode Safety System and error protection.

ERBOTOM ICC 350 Z Neurotest Functionality

Intended Use and Neurotest Connections

Explains the Neurotest device's purpose and its connections.

Neurotest Operation Basics

Neurotest Operation Basics and Principles

Details the Neurotest device's operation and underlying principles.

ERBOTOM ICC 350 T Neurotest Functionality

Intended Use and Neurotest Connections (ICC 350 T)

Explains the Neurotest device's purpose and its connections for ICC 350 T.

Neurotest Operation Basics (ICC 350 T)

Neurotest Operation Basics (ICC 350 T)

Details the Neurotest device's operation and principles for ICC 350 T.

ERBOTOM ICC 350 M Specialized Features

MIC/MIN Instruments and Air Input

Describes intended use with MIC/MIN instruments and air connection.

MIC Instrument Operation and Setup

MIC Instrument Operation and Setup

Details operation of MIC instruments and initial installation.

Instrument Identification System (IIS)

Explains automatic instrument recognition and configuration.

MIN Instrument Operation and Technical Data

MIN Instrument Operation and Technical Data

Details MIN instrument operation and associated technical data.

ERBOTOM ICC 350 M-DOKU Data Recording System

M-DOKU Intended Use and System Setup

Describes the M-DOKU's purpose and PC/system setup.

Software Installation and Menu Navigation

Software Installation and Menu Navigation

Covers software setup and main menu function key usage.

Technical Data: Cutting Modes

AUTO CUT and HIGH CUT Specifications

Lists technical data for AUTO CUT and HIGH CUT modes.

Bipolar Cutting and Program 'b' Data

Provides technical specifications for bipolar cutting and Program 'b'.

ENDO CUT, Soft, Forced, and Spray Coagulation Data

Lists technical data for ENDO CUT, Soft, Forced, and Spray coagulation.

AUTO BIPOLAR, Safety, and Programmability

Details AUTO BIPOLAR specs, safety features, and programmability.

Power, Classification, and Environmental Data

Covers power connection, EC classification, and environmental conditions.

Visual and Acoustic Signal Reference

Signal Status and Meanings

Summarizes unit status signals and their interpretations.

Operational Diagrams and Charts

CUT Mode Voltage vs. Power Diagrams

Illustrates voltage vs. power for AUTO CUT and BIPOLAR CUT modes.

HIGH CUT Voltage vs. Power Diagrams

Illustrates voltage vs. power for HIGH CUT mode.

Soft Coag/Auto Bipolar Voltage vs. Power

Illustrates voltage vs. power for Soft Coagulation and Auto Bipolar.

Forced Coagulation Voltage vs. Power

Illustrates voltage vs. power for Forced Coagulation.

Spray Coagulation Voltage vs. Power

Illustrates voltage vs. power for Spray Coagulation.

CUT Mode Power Output vs. Load Resistance

Shows power output vs. load resistance for CUT modes.

Soft Coag/Auto Bipolar Output vs. Load

Shows power output vs. load resistance for Soft Coag/Auto Bipolar.

Forced Coagulation Output vs. Load

Shows power output vs. load resistance for Forced Coagulation.

Spray Coagulation Output vs. Load

Shows power output vs. load resistance for Spray Coagulation.

Bipolar Cut Output vs. Load Resistance

Shows power output vs. load resistance for Bipolar Cut.

Auto Cut Power Output vs. Limitation

Illustrates power output versus power limitation for Auto Cut.

High Cut Power Output vs. Limitation

Illustrates power output versus power limitation for High Cut.

Soft Coag/Auto Bipolar Output vs. Limitation

Shows power output versus limitation for Soft Coag/Auto Bipolar.

Forced Coagulation Output vs. Limitation

Shows power output versus limitation for Forced Coagulation.

Spray Coagulation Output vs. Limitation

Shows power output versus limitation for Spray Coagulation.

NESSY System Warning Signal Logic

Signal Dependencies on Resistance and Current

Explains NESSY warning signals based on resistance and HF current.

Installation and Environmental Considerations

Room Requirements and Power Connection

Covers spatial needs, grounding, and safe power connection.

Explosion Protection and Setup

Addresses explosion hazards and general setup procedures.

Moisture, Cooling, Interference, and Inspection

Details protection against moisture, cooling, interference, and unit inspection.

Custom Time Limit Adaptation

Explains how to adapt maximum time limits for operation modes.

Procedure for Custom Time Limit Adaptation

Step-by-step guide for adjusting maximum time limits.

Forced Coagulation Versions and Electrode Switching

Details Forced Coagulation versions and neutral electrode switching modes.

Cleaning and Disinfection Procedures

Safe Unit Cleaning and Disinfection

Provides guidelines for cleaning and disinfecting the unit safely.

Performance Checks and Error Detection

Post-Power-On and Activation Checks

Details automatic checks performed on startup and during activation.

Automatic Error Logging and Retrieval

Describes how errors are recorded, signaled, and retrieved.

Comprehensive Error List and Solutions

Error Code Descriptions and Troubleshooting Steps

Lists error codes and provides recommended actions for resolution.

Mandatory Safety Checks

Established ICC Safety Check Procedures

Lists the required safety checks for the ICC unit and their frequency.

Maintenance, Care, and Disposal

Unit Maintenance, Repairs, and Care

Covers routine maintenance, safe repairs, and unit care practices.

Disposal Guidelines

Provides instructions on how to properly dispose of the unit.

Guarantee and Customer Support

Customer Service Contact Information

Information on how to contact ERBE for service and inquiries.

Guarantee Terms and Conditions

Details the conditions, duration, and scope of the product guarantee.