Do you have a question about the Erbe VIO 100 C and is the answer not in the manual?
Type | Electrosurgical Unit |
---|---|
Brand | Erbe |
Model | VIO 100 C |
Output Power | 100 W |
Mains Voltage | 100-240 V |
Mains Frequency | 50/60 Hz |
Modes | Cut, Coagulate, Blend |
Mode | CUT, COAG |
Explains the meaning and purpose of different safety warning symbols.
Emphasizes the importance of the User Manual for service personnel.
Details precautions to prevent electric shock hazards during operation and maintenance.
Warns about handling ESD-sensitive components and outlines necessary precautions.
Outlines liability and warranty conditions related to servicing and use of parts.
Describes the controls and indicators located on the front panel of the unit.
Details the controls and connectors found on the rear panel of the unit.
Explains the two levels of service mode: Setup and Service.
Details the procedures and functions for accessing and using setup mode for unit configuration.
Provides an overview of available service programs and their uses for diagnostics and inspection.
Instructions on how to access the Service mode and Setup mode, including exit procedures.
Crucial safety warnings regarding servicing and repairs, emphasizing authorized personnel.
Lists and explains error codes, their causes, and recommended actions for troubleshooting.
Defines authorized personnel for servicing and maintenance tasks.
Covers the definition and recommended frequency for technical safety checks.
Provides a detailed, step-by-step guide for conducting a technical safety check.
Safety precautions relevant to performing the technical safety check.
Lists the necessary testing and measuring equipment required for servicing.
Covers user manual checks, visual inspections, and tests according to national regulations.
Details the procedure and equipment for testing DC resistance.
Covers setup and step-by-step instructions for executing the DC resistance test.
Lists various performance tests and their associated equipment.
Details the setup and steps for executing performance tests.
Covers testing of activation tones and footswitch functionality, including specific CUT/COAG tests.
Covers testing of fingerswitch and AUTO START mode, including CUT/COAG procedures.
Covers setup and step-by-step instructions for testing the AUTO START mode.
Procedure for testing the HF power output for CUT functions.
Procedure for testing the HF power output for COAGULATE functions.
Test procedure for BIPOLAR SOFT COAG mode.
Covers testing of monitor circuits and specific NE monitoring critical resistance tests.
Second phase of testing for monitor circuits.