80114-831 2019-05
QUICK GUIDE
IES
3
This quick guide is no substitute for briefing and user manual. This quick guide does not include any safety notes. Make yourself familiar
with the safety notes in the user manuals.
Necessary operating steps
Depending on which electrosurgical unit you are working with, certain
preparation steps are necessary.
Read the appropriate chapter in this User Manual: e.g. The IES 3 in
combination with a VIO 3 electrosurgical unit.
Connect the desired accessories, e.g. prefilter, water trap, instru-
ment.
Compared to the OPEN mode, the LAP mode has a lower suction capac-
ity with the same settings, and doesn’t have a turbo button. These fea-
tures of the LAP mode serve to protect the patient during laparoscopic
surgery and to support the stability of the pneumoperitoneum.
You can suction with the settings of the device or choose to change the
settings (see back).
Option 1
You use the IES 3 with an Erbe electrosurgical unit VIO 3, VIO D/S
series and the devices are connected to each other.
You use the IES 3 with any desired electrosurgical unit and the au-
tomatic activation device is installed.
Activating the HF instrument.
The IES 3 starts automatically.
Option 2
You use the IES 3 without connection with an Erbe electrosurgical
unit and without an automatic activation device.
Activate the IES 3 with the footswitch or with the activation but-
ton on the touchscreen of the device.
Activation screen: The segments on the right-hand side of the screen
show the course of the suction shut-off delay. The segments on the
left-hand side of the screen show the course of the standby suction
time (not visible in the image).
Order of suction types
So long as you activate the HF instrument or press the footswitch or
activation button, suction is active. If you have selected times above
0 s in the Settings menu, the suction shut-off delay and the standby
suction time will follow respectively.
Observe the remaining filter display and the messages on the touch-
screen.
!
1 Preparing the IES 3
2 Connecting the accessories
3 Switch on the device
4 Select the suction mode
5 Suctioning
6 Checking the filter capacity

Other manuals for Erbe IES 3

Question and Answer IconNeed help?

Do you have a question about the Erbe IES 3 and is the answer not in the manual?

Erbe IES 3 Specifications

General IconGeneral
BrandErbe
ModelIES 3
CategoryMedical Equipment
LanguageEnglish

Summary

Necessary Operating Steps

Preparing the IES 3

Details on preparing the electrosurgical unit, including reading the user manual for specific combinations.

Connecting Accessories

Instructions for connecting necessary accessories like prefilters, water traps, and instruments.

Switching on the Device

Guidance on powering on the IES 3 device.

Selecting Suction Mode

Explains the difference between OPEN and LAP suction modes and their features.

Suctioning Operation

Information on suctioning using device settings or changing settings, with options for different IES 3 configurations.

Checking Filter Capacity

How to monitor the remaining filter capacity and system messages on the touchscreen.

Optional Operating Steps

Accessing OPEN Settings

Instructions on how to access and navigate the OPEN settings menu on the device.

Setting OPEN Suction

Details on adjusting the suction capacity for the OPEN suction mode.

Setting OPEN Suction Shut-off Delay

Procedure for setting a specified time for the OPEN suction to continue after deactivation.

Setting Standby Suction

Guidance on setting reduced capacity suction for use during work breaks.

Setting Standby Suction Time

Instructions for setting the duration for standby suction operation.