Service manual
ERBE
ICC 200
ICC 300 H-E
ICC 350
09.2004

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Erbe ICC 300 H-E and is the answer not in the manual?

Erbe ICC 300 H-E Specifications

General IconGeneral
BrandErbe
ModelICC 300 H-E
CategoryMedical Equipment
LanguageEnglish

Summary

Test Programs and Adjustments

Calling Up Test Program Mode

Procedure for entering and navigating the test program menu.

Basic Settings of SETUP Parameters

Configuration of initial device settings before test programs.

ICC 200 Front Panel Settings

Factory settings for the ICC 200 front panel displays.

ICC 300 Front Panel Settings

Factory settings for the ICC 300 front panel displays.

ICC 350 Front Panel Settings

Factory settings for the ICC 350 front panel displays.

Test Program 1: Basic Front Panel Setting

Allows setting and storing of front panel configurations as basic settings.

Test Program 2: Error List and Display

Displays and manages the unit's error history and memory.

Test Program 3: D-Flipflop Circuit Test

Verifies the functionality of D-flipflop circuit memories.

Test Program 4: Front Panel Optical Signals

Checks all optical displays and 7-segment displays on the front panel.

Test Program 5: Sound Control and Frequency

Tests and sets all available sounds and their frequencies.

Test Program 6: Relay Test

Actuates all relays to verify their functionality.

Test Program 7: NESSY Version Setting

Allows setting of different NESSY versions for specific electrode types.

Test Program 8: Software and Option Display

Displays the software version and option identification numbers.

Test Program 9: Display Program Activation

Activates display programs to show measurement values.

Test Program 10: Maximum Time Limit Adjustment

Allows modification of the maximum time limit for unit operations.

Test Program 11: Measurement Channel Output

Measures and displays internal voltages, temperature, and analog channels.

Test Program 12: FORCED Voltage Setting

Sets the FORCED voltage versions for coagulation.

Test Program 13: LF Leakage Current Monitor

Monitors low-frequency leakage current for cardiac floating designation.

Test Program 16: Measuring Equipment and Jumper Settings

Lists recommended measuring equipment and details jumper configurations.

Test Program 17: 7-Segment Display Brightness

Adjusts the brightness of the 7-segment displays in 10 stages.

Test Program 23: AUTO START Delay Time

Modifies delay time specifications for AUTO START activation.