Initial Configuration and Commissioning
20
3/1531-HSD 101 41 Uen E 2007-08-13
7 Initial Configuration and Commissioning
7.1 Embedded Nodes
It is not needed to do any configuration for either ESN212 or EDN612. The
default settings for the ESN212 switch are following:
IGMP Snooping Enabled
DHCP Interception Enabled
Management VLAN 247
Untagged Management VLAN 1
RSTP and MSTP Disabled
7.2 Stand Alone ESN212
When the ESN212 is not embedded it must be configured for static IP and
for the management VLAN. To make the initial configuration a terminal (or
a PC with a terminal emulation application such as HyperTerminal) and a
consol connection cable are needed. The consol cable is not delivered with
the ESN212.
Consol Connection Cable
Use a standard straight through LAN cable with a standard converter, or
make a cable with the following connections: