Initial Configuration and Commissioning
3/1531-HSD 101 41 Uen E 2007-08-13
21
Figure 13 RJ-45 and D-SUB 9 Pin Numbering
Table 8 Console Cable RJ-45 to D-SUB 9 Pin Assignment
RJ-45 Pin Signal Name D-SUB 9
1 Not used -
2 Not used -
3 Not used -
4 ------- Ground ---------- 5
5 RXD -----<-------- TXD 3
6 TXD ------->------ RXD 2
7 Not used -
8 Not used -
1. Connect the cable to the Console terminal
2. Set the following setting in the terminal emulation application:
Data rate to 9600 baud.
Data format to 8 data bits, 1 stop bit, and no parity.
Flow control to none, emulation mode to VT100
3. Logon to the ESN212 with the username admin and password admin.
4. Set the management VLAN to the VLAN used in the network (if this
VLAN is different from 247. For example 246:
5
1
6
9
RJ45
1
8
D-SUB 9 female