Installing and Upgrading the Software
22
3/1531-HSD 101 41 Uen E 2007-08-13
ESN212# management vlan 246
5. Configure IP parameters. In the following example the following
parameters are set:
IP address 172.30.10.100
Subnet mask 255.255.255.0
Trap receiver 172.30.10.10
SNTP server 172.30.10.10
Default gateway 172.30.10.1
Note that Trap receiver, SNTP server and default gateway must be
configured even though they might be overwritten by a management
system (PEM for example).
esn212# boot mode manual ip address 12.30.10.100
255.255.255.0 trap receiver 12.30.10.10 sntp server
12.30.10.10 def gateway 12.30.10.1
6. Restart the ESN212:
esn212# restart
Note that the settings are automatically saved. It is therefore not necessary
to save them manually before the restart.
8 Installing and Upgrading the Software
Both application and boot SW of the ESN212 and EDN612 is upgraded
from the ECN330 Ethernet Controller Node (CLI) or from a management
system. See the management system documentation or the ECN330 User
Guide for instructions.