EMC Capabilities
Table 165 Magnetic field emission
Limit standard VDE 0878, Magnetic emission, part 1
Limit Class B
52.3.4 Conducted Immunity on AC Input Power Ports
Table 166 Fast transient test
Basic standard EN 61000-4-4
Test level 4 kV common mode between all lines and cabinet ground reference
Performance Criteria B
Limit standard ETS 300 342-2
Test level 4 kV common mode between all lines and cabinet ground reference
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 167 Surge test
Limit standard ETS 300 342-2
Test level 2 kV common mode between all lines and cabinet ground
reference
1)
1 kV differential mode, between line and line
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
1)
System primary protected
Table 168 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Table 169 Voltage dips and interruptions on AC ports
Basic standard EN 61000-4-11
Performance Criteria A for a complete system