EMC Capabilities
52.3.5 Immunity on DC Input/Output Power Ports
Table 170 Fast transient test
Basic standard
EN 61000-4-4
Test level 2 kV common mode between all lines and cabinet ground reference
Performance Criteria B for a complete system
Limit standard ETS 300 342-2
Test level 2 kV common mode between all lines and cabinet ground reference
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 171 Surge test
Limit standard ETS 300 342-2
Test level 1 kV common mode between line and cabinet ground reference
0.5 kV differential mode, between line and line
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 172 RF common mode test
Limit standard ETS 300 342-2
Test level 3 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
52.3.6 Immunity on Telecommunication and External Signal Lines
Table 173 Fast transient test
Basic standard EN 61000-4-4
Test level 2 kV common mode between line and cabinet ground reference
Performance Criteria B
Limit standard ETS 300 342-2
Test level 4 kV common mode between line and cabinet ground reference
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units