Insulaon R-value to be R1.5 and of malleable/exible construcon (rock wool or glass wool) and cered to
withstand 230°C.
Tape must be used for all overlapping joints and the enre ue must be wrapped. Care must be taken not to
compress insulaon.
Running the Power Flue Electrical Cable
Note: The Power Flue Terminal is powered from the appliance, and must be connected to the appliance with
the supplied electrical cable only.
Note: Ensure that the appliance power supply is disconnected before making the connecon to the terminal.
The supplied electrical cable is 7m long, ue extension kits also include a Power Flue electrical cable extension.
Run the electrical cable from the cavity where the appliance will be installed to the hole in the outside wall.
Ensure it is not draped over, or in contact with, the outer shell of the appliance or the exhaust ue and kept
clear from any other possible heat sources, sharp edges, or moisture. Fix it appropriately and allow enough
cable looped to be able to pull both the appliance and the Horizontal Power Flue Wall Terminal out from their
installed posions.
IF YOU DO NOT CONNECT THE POWER FLUE ELECTRICAL CABLE TO BOTH THE FIREPLACE AND THE