51
Error Codes
This gas re has been designed to show error codes to help explain and idenfy any fault situaon that occurs.
These codes will appear on the top of the remote touchscreen in the form of a leer “E” with a number code
beside it. Codes can normally be reset by turning the replace o then on again at the mains power wall switch.
The following table shows what each code means and possible ways to recfy the situaon. In the case of
persistent or repeated shutdown errors, acon must be taken immediately to nd and repair the fault.
Some codes are not applicable for this model or are for factory diagnoscs. These have not been included in this
table.
NOTE: An error code may not signify a fault/warranty issue; depending on the error code, it may signify that
the remote baeries are low or the LPG cylinder is empty. Refer to the secon below and contact Escea if
needed.
Error Code Suggested acon
E1
Electronics Over Temp
Ensure correct gaps are present around glass. Check fascia and trims are
correctly ed.
Room air fan/s may be slowed or stalled. Check that the fans are plugged in,
clean, and free turning.
Check for excess lint and dust build-up on the PCB/Controller.
E2.1
The re has tried to light
three mes and failed during
a normal startup.
Check correct gas pressure to the appliance with all other appliances running.
Check the spark electrode is sparking at the end of each 15s - 30s purge.
Check the electrode is well enveloped in ame. Ensure no small embers/coals
have dropped onto the ignion electrodes inside the pilot guard.
Ensure the electrode is not contacng any metalwork.
E2.2
Waited too long for purge to
nish.
The re has completed its purge but has not aempted to ignite the pilot.
E2.3
Three failures during normal
runme.
Check gas supply and check other gas appliances to see if they are aected. If
you have two separate LPG cylinders, switch over to the full bole or contact
your gas supplier. You may need to retry igning the re a few mes aer re-
establishing gas supply.
E2.5
Pilot has exnguished
when the re is in over-
temperature mode.
The re has moved to over-temperature mode (pilot ame only) and the pilot
has exnguished. Check pilot jet for obstrucons.