2. Installation
2.1 Installation Safety Instructions
The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations.
Isolate mains supply before commencing installation. Please
read all instructions before proceeding.
Ensure that the fixed wiring connections to the mains supply is
via a fuse rated at not more than 6 amps and class ‘A’ switch
having a contact separation of a minimum of 3mm in all poles.
The recommended cable sizes are 1.0mm sqr or 1.5mm sqr. No
earth connection is required as the product is double insulated
but ensure continuity of earth throughout the system.
2.2 General Safety Instructions
When fitting batteries, do not mix old and new batteries
together. Do not use rechargeable batteries.
This product complies with the essential requirements of the
following EC Directives:
• Electro-Magnetic Compatibility Directive 2014/30/EU
• Low Voltage Directive 2014/35/EU
• EC Marking Directive 93/68/EEC
• R&TTE Directive 1999/05/EC