8 - Essentials Pro 2
Push-button Chuck Maintenance (Fig. 7)
Note: It is recommended that push-button chuck be cleaned every 3 - 4 maintenance cycles.
1. Remove bur.
2. Detach handpiece from air supply.
3. Insert spray nozzle tip of Henry Schein Spray & Clean into chuck and dispense spray for 1 - 2 seconds.
4. Work chuck mechanism to distribute cleaner/lubricant by repeatedly pressing button.
5. With push button depressed, insert and remove bur several times to break-up remaining debris.
6. Wipe off excess cleaner/lubricant with a dry, lint-free cloth.
Fig. 7
Cleaning Water Spray Ports (Fig. 8)
Note: It is recommended that spray ports be periodically cleaned.
1. Carefully clean ports using cleaning wire supplied with handpiece.
2. Connect handpiece and run with water flow activated to confirm ports have been fully cleared
of debris.
3. Repeat steps 1 and 2 as necessary.