  • D
    David GonzalezAug 11, 2025
    How to troubleshoot Etac Medical Equipment lift that does not function?
    • J
      Joshua ClarkeAug 11, 2025
      If your Etac Medical Equipment lift isn't working, start by checking the power. Ensure the emergency stop is released by turning it a quarter turn until it springs out. Also, check if the battery is discharged or defective, and charge or replace it if necessary. Make sure the electric sockets are properly inserted. Finally, remove the power cord from the power outlet if it's connected.
  • N
    Nicholas JohnsonAug 16, 2025
    Why is my Etac Nova 300 NG Medical Equipment lift moving slowly?
    • N
      Nancy Bowman MDAug 17, 2025
      If your Etac Medical Equipment lift or base width movement is slow and the light on the hand control is on, the issue might be an inadequate power supply, a defective power cord, or a defective electrical box. Try charging or replacing the battery. If that doesn't work, replace the power cord or the electrical box.
  • M
    Marcus MorrisAug 23, 2025
    What to do if Etac Nova 300 NG lift only moves in one direction?
    • J
      Jasmine McknightAug 23, 2025
      If your Etac Medical Equipment lift only goes up or down (not in both directions) or the base width can only be adjusted in one direction, it could be due to a contact fault, a fault in the electrical box, an inadequate power supply, or a loose connection in the hand control. Try charging or replacing the battery. If that doesn't resolve the issue, replace the hand control or the electrical box.
  • G
    gonzalezcherylAug 29, 2025
    How to fix Etac Medical Equipment base width adjustment that is not working?
    • D
      Douglas HernandezAug 29, 2025
      If the base width adjustment on your Etac Medical Equipment does not function, it may be due to a contact fault. Try pushing the contacts together.
  • H
    hernandezrichardSep 4, 2025
    Why is my Etac Nova 300 NG lift making strange noises?
    • T
      Tracy MeyersSep 4, 2025
      If your Etac Medical Equipment lift is making abnormal noises, it could be due to a motor fault or resistance at the motor’s attachment points. Loosen and check/adjust the tightness of the motor’s attachment points or contact Etac.