Do you have a question about the Etatron DLX-pH/M SERIES and is the answer not in the manual?
Category | Water Pump |
---|---|
Model | DLX-pH/M SERIES |
Hose Connection | 4/6 mm |
Protection Class | IP65 |
pH Control | Yes |
Mounting | Wall |
Power Supply | 220-240V AC |
Material | PVDF, PTFE |
Any intervention or repair to internal parts must be by qualified personnel.
Pump should be moved vertically; delivery is at purchaser's risk. Claims within 10 days.
Use only for dosing liquid additives; improper use is dangerous and voids responsibility.
Check for damage after unpacking; keep packing away from children; verify voltage.
Avoid contact with hazardous liquids; follow manufacturer notes and use correct materials.
Consult exploded view for assembly. Dismantlement requires disconnecting power and relieving pressure.
Pump activated by electromagnet/diaphragm; simple operation, low maintenance, suitable for aggressive liquids.
Products comply with EEC regulations, IP65 protection, antiacid casing, control panel protection.
Lists materials for diaphragm, pump head, nipples, hoses, valves, and seals for the DLX/DLXB series.
Diagram and list of parts for installing the injection valve.
Details wiring for level probe and mA signal output connections.
Instructions for adjusting stroke length on DLXB series pumps using a knob.
Identifies and describes the function of each control button and LED on the pump interface.
Diagram showing the physical setup of the pump with its components and connections.
Lists the standard accessories included with the pump.
Explains the level control function and associated indicators (alarm, yellow LED).
Step-by-step guide for installing, connecting, and calibrating the pH controller pump.
Details how to set the desired pH value and configure hysteresis and delay times.
Explains how to configure the pump for dosing acid or alkaline solutions based on pH needs.
Describes how the pump adjusts dosing frequency proportionally to the set point.
Lists and briefly describes available functions (F1D, F1A, F2D, F2A, F3D, F3A).
Instructions on how to activate or deactivate pump functions using the 'F' and directional buttons.
Identifies and describes the function of each control button and LED on the Rx controller pump interface.
Diagram showing the physical setup of the Rx controller pump with its components and connections.
Lists the standard accessories included with the Rx controller pump.
Explains the level control function and associated indicators for the Rx controller pump.
Step-by-step guide for installing, connecting, and calibrating the Rx controller pump.
Details how to set the desired Rx value and configure hysteresis and delay times.
Explains how to configure the Rx pump for dosing oxidative or reductive solutions.
Describes how the Rx pump adjusts dosing frequency proportionally to the set point.
Lists and briefly describes available functions for the Rx controller (F1D, F1A, F2D, F2A, F3D, F3A).
Instructions on how to activate or deactivate Rx controller functions using the 'F' and directional buttons.
Discusses common mechanical issues like loose nuts, broken tubing, or membrane seal failures.
Covers electrical issues such as LEDs being off, pump not pulsing, or pulses being inconsistent.
Explains how to clean electrodes to ensure accurate readings, covering thin deposits and chemical cleaning.
Details complete injection valves with fittings, including standard, 1/2", and 90° types.
Describes lip valves for 20 l/h and 30-50 l/h applications, and gravity ball valves.
Lists special valves such as gravity ball, suction, discharge, and Kalrez valves.