setting temperature at the first filter cycle(The heater will not work at the second filter cycle).
5) The 4th time to press “ ”, the system goes back to “Filter Mode” and the LCD is
showing “ ”, the system will just work under the filter cycle and the heater doesn’t work.
4. Automatically Anti-freeze Function
When the water temperature is less than 44℉/6.7℃ or much lower, anti-freeze function will
automatically start up, all the pumps and blower work for 30 seconds and then turn off, then all
the heaters and circulation pumps turn on, and the LCD is showing “ ”.
When the water temperature reach to 46℉/7.8℃ or above, the heater will stop working and
the circulation pump will turn off after several seconds delay.
4. To ensure the lifetime of heater’s relay, the heater will automatically shut down once every 40
minutes for 40s(Hot pump is 3 minutes).
Ⅳ). Clock Setting
At clock setting status ( Fig. 4), press “ ” key to set hours (down button), the adjustable
range is “0 ~ 23”. And press “ ” key to set minutes (up button), the adjustable range is “0
~59”.
Fig. 7:Current time is 12:34 Fig. 8:Start time of filtration is 3:00 o’clock
Ⅴ). Pre-settings for Filter Anti-virus Cycle (Only valid when A1=OFF)
1. The system will execute filter cycle twice each day, but the user can only set up the start time
for the 1st filter cycle, the start time of the 2nd filter cycle will automatically increase and start
up after 12 hours.(Example: The start time of the 1st filter cycle is 14:00, then the 2nd filtration
start time will be 2:00)
2. When A2 = ON, the time for filter cycle is fixed and it will start up at 14:00 every day and lasts
for 3 hours. The start time of the 2nd filtration is 2:00.
3. When A2= OFF and the system is under the status of “start time of filtration setting” (Fig. 8),
press “ ” key to change the start time for hours, the “minutes” setting is always 00(It means
the minimum time range is hours).
4. Under the status of “continuous working period of filter cycle setting”, press “ ” key to
change the period, the setting range is 1-11 hours (Fig. 9).