E14060543
Directive : 2004/108/EC Electromagnetic Compatibility Directive
For the most specific risks of this machine, safety and compliance with the essential
requirements of the Directive has been based on elements of:
EN 61000-6-3:2007/A1:2011 / Electromagnetic compatibility (EMC) -- Part 6-3: Generic standards -
Emission standard for residential, commercial and light-industrial environments
EN 55011:2009/A1:2010 / Industrial, scientific and medical equipment - Radio-frequency distur
bance
characteristics - Limits and methods of measurement CISPR 11:2009 (Modified)
EN 61000-6-1:2007 / Electromagnetic compatibility (EMC) -- Part 6-1: Generic standards - Immunity
for residential, commercial and light-industrial environments
IEC 61000-4-2:2008 / Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+A1:2007+A2:2010 / Electromagnetic compatibility (EMC) - Pa
rt 4-3: Testing and
measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-8:2009 / Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement
techniques - Power frequency magnetic field immunity test
Date :
Signature :
Qualification :
General Manager
Place : Taichung City, Taiwan
EVAK PUMP TECHNOLOGY CORP.
No.551, Zhongshan Rd., Qingshui Dist., Taichung City 436, Taiwan (R.O.C.)
1.DPC-10 Panel introduction
2.Technical data
Supply voltage:115~220Vac ± 10% 50/60HZ
Maximum ambient temperature:
+40℃
Maximum liquid temperature:
+65℃
Maximum system pressure:
10bar
Maximum contact load AMP:
12A
Ingress Protection Rating:
IP55
Dry Running
Digital Pressure Controller
DPC-10
bar
kg/cm
2
psi
Over Pressure
Power :115-220Vac ±10% 50/60HZ
Max :12A / Max :10bar / IP55
Model Number
LED Light
LCD Display
Technical Data
Button
Pressure Unit
»
»
»
»
»
»
»
Relay Capacity: 1HP in 110V or 2HP in 220V
»
The Max. motor size is 1HP in 110V or 2HP in
220V, but if connect to contactor in the control
panel then DPC-10 controller can fit the pump
over 2HP.