EVAPCO AT 14-912 User Manual

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Bulletin 113-E Metric
EVAPCO Products are Manufactured Worldwide
EVAPCO, Inc. (World Headquarters) P.O. Box 1300, Westminster, Maryland 21158 USA
Phone (410) 756-2600 - Fax (410) 756-6450
EVAPCO Europe bvba
Heersterveldweg 19
Industrieterrein Oost
3700 Tongeren, Belgium
Phone: (32) 12 395029
Fax: (32) 12 238527
E-mail: evapco.europe@ evapco.be
EVAPCO Europe S.r.l.
Via Ciro Menotti 10
I-20017 Passirana di Rho
Milan, Italy
Phone: (39) 02 9399041
Fax: (39) 02 93500840
Email: evapcoeurope@evapco.it
EVAPCO Europe GmbH
Insterburger Straße, 18
D-40670 Meerbusch, Germany
Phone: (49) 2159-6956-0
Fax: (49) 2159-6956-11
Email: info@evapco.de
EUROPEAN
OPERATION AND MAINTENANCE INSTRUCTIONS
For EVAPCO Induced Draft and Forced Draft Cooling Towers
For EVAPCO Authorized Parts and Service,
Contact Your Local Mr. GoodTower
®
Service Provider
or the EVAPCO Plant Nearest You
www.evapco.eu
AT UAT LSTE LPT PMTQ

Table of Contents

Questions and Answers:

EVAPCO AT 14-912 Specifications

General IconGeneral
BrandEVAPCO
ModelAT 14-912
CategoryAccessories
LanguageEnglish

Summary

Introduction

General Safety Guidelines

Provides essential safety guidelines for operating and maintaining the cooling equipment.

Installation and Storage Precautions

Initial and Seasonal Start-Up Checklist

Maintenance Checklist

Seasonal Shut-Down Checklist

Basic Cooling Tower Sequence of Operation

Fan System Components

Fan Belt Adjustment

Fan System - Capacity Control

Capacity Control Methods

Covers fan motor cycling, two-speed motors, and variable frequency drives for capacity control.

Resonant Frequencies and Water System Maintenance

Identifying and Locking Out Resonant Frequencies

Procedures for identifying and locking out resonant frequencies in VFD systems.

Water Treatment and Water Chemistry

Galvanized Steel Passivation

Procedure for passivating galvanized steel to prevent white rust during start-up.

Water Chemistry Parameters and Biological Control

Recommended Water Chemistry Guidelines

Table of recommended water chemistry parameters for different materials.

Microbiological Control Procedures

Importance of regular inspection and control of microbial populations to prevent fouling.

Gray Water, Air Contamination, and Stainless Steel

Cold Weather Operation

Cold Weather Capacity Control and Accessories

Capacity Control Methods for Cold Weather

Strategies for controlling capacity in cold weather for both unit types.

Ice Management

Ice Management for Induced Draft Units

Methods for managing ice buildup in induced draft units during cold weather.

Ice Management for Forced Draft Units

Strategies for managing ice formation in forced draft units.

Troubleshooting: Fan Motors and Spray Patterns

Fan Motor Issues

Diagnosing and resolving problems with fan motors, including overamping and noise.

Spray Pattern Problems

Diagnosing and fixing issues with the water spray pattern.

Troubleshooting: Noise, Scaling, and Valves

Fan Noise and Louver Scaling

Troubleshooting fan noise and cleaning scaled inlet louvers.

Troubleshooting: Water Levels and Stainless Steel

Water Level Control Faults

Resolving low pan water levels and electric level control faults.