EasyManua.ls Logo

EVE LF280K - Cycle Life

EVE LF280K
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-15
-EVE PowerCO.,LTD Confidential Proprietary-
Model
LF280K
Specification No
PBRI-LF280K-D06-01
Version
C
Store the cell for 28 days at 25°C±2°C and rest for 5 h at 25°C ±2℃;
Discharge to 2.5 V at a constant power of 448W and rest for 30 min;
Charge to 3.65 V at a constant power of 448W and rest for 30 min,note the energy as Eg;
Discharge to 2.5 V at a constant power of 448W and rest for 30 min,note the energy as Eo*;
Charge energy recovery rate =Eg/Eo*100%; discharge energy recovery rate=Eio*/E*100%.
3.14.2 45°C Storage
Charge the cell according to (3.8)at the ambient temperature of 25°C ±2℃;
Discharge for 60 min at a constant powerof448 Wand rest for 30 min;
Store the cell for 28 days at the ambient temperature of 45°C±2°C and rest for 5 h at the
ambient temperature of 25±2;
Discharge to 2.5 V at a constant powerof448 W and rest for 30 min;
Charge to 3.65 V at a constant powerof448 W and rest for 30 min;
Discharge to 2.5 V at a constant powerof448 Wand rest for 30 min,note the energyas E10*;
Discharge energy recovery rate =E10*/Eo*100%.
3.15 Cycle life
3.15.1 25 Cycle
Before the test,prepare and install the clamp according to 3.3.1
Pre-cycle initial capacity test:test the cell energy according to (3.10).
Cycle test:at ambient temperature of 25°C±2℃;
a. Discharge the cell in accordance with (3.9);
b.Charge the cell to 3.65 V at a constant power of 448 W and rest for 30 minutes;
c.Discharge to 2.5 V at a constant powerof448 W and rest for 30 minutes;
d.Repeat steps b~c6000 times.
b. 448 W 3.65 V, 30 min;
c.448 W 2.5 V, 30 min;
d.b~c 6000cycle
Capacity test after cycling at ambient temperature of25°C±2℃: